TB-9037
Page 1 of 10
© 2016 DESCO INDUSTRIES, INC.
Employee Owned
SCS
- 926 JR Industrial Drive, Sanford, NC 27332
East: (919) 718-0000 | West: (909) 627-9634 • Website:
StaticControl.com
EM Aware Monitor
Installation, Operation and Maintenance
December 2016
Description
The SCS EM Aware Monitor monitors up to three key
parameters that keep you aware of critical symptoms
of ESD problems: ESD events, change in static voltage
field, and ionizer performance*. The thresholds for
these parameters are fully adjustable. The monitor is
constructed of an aluminum enclosure, LCD display,
control joystick, remote antenna, power adapter and
data output terminal.
ESD events generate electromagnetic radiation.
The stronger the ESD event, the stronger the
electromagnetic radiation. The EM Aware Monitor is a
miniature radio receiver tuned to detect and measure
the unique waveform generated by an ESD event.
The EM Aware Monitor and its accessories are available
as the following item numbers:
Item
Description
CTC034-030-3-WW
EM Aware Monitor, ESD Events,
4.20mA Output
CTC034-030-5-WW
EM Aware Monitor, ESD Events,
Modbus Output
CTC034-031-5-WW
EM Aware Monitor, ESD Events,
Static Field & Ionization, Modbus
Output
770038
Data Logger, Dataq DI-710, for EM
Aware Monitor
CTA212
Power Adapter, 100-240VAC Input,
12VDC 1.5A Output, All Plugs
CTC111-6FT
Antenna, Room Temperature, 6 ft.
CTC118-6FT
Antenna, High Temperature, 6 ft.
CTC118-10FT
Antenna, High Temperature, 10 ft.
Made in the
United States of America
Figure 1. SCS EM Aware Monitor
USER GUIDE TB-9037
Packaging
1 EM Aware Monitor
1
CTC111-6FT
Antenna with 6 ft. Cable
1 Monitor Ground Cord (Green and Yellow)
1 Power Adapter, 12VDC, with interchangeable plugs
(North America, UK/Asia, Europe)
1 Certificate of Calibration
Features and Components
*Ionization monitoring is only available in item CTC034-031-5-WW.
Compatible with critical environment ionizers only. The ionizer must
have a balance (offset voltage) of ±5V or better.
A. Antenna Input:
Connect to the antenna using the
included cable.
B. LCD Display:
Displays measurements and settings.
C. Joystick:
Toggles displayed measurements and
monitor settings.
D. Power Jack:
Connect the included 12VDC power
adapter here.
E. Ground Terminal:
Common ground point for the
monitor.
F. Data Output:
Model
CTC034-030-3-WW
outputs
a 4.20 mA analog signal for use with the
770038
Data
Logger.
Models
CTC034-030-5-WW
and
CTC034-031-5-WW
output Modbus serial communication for use with
Static
Management Program (SMP)
.
Figure 2. EM Aware Monitor features and components
F
E