Specifications

Resistance Ranges

1 x 10

3

 to 1 x 10

6

 ohms @ 10 

Volts, complies with ANSI/

ESD S4.1
1 x 10

6

 to 1 x 10

12

 ohms @ 

100 Volts, complies with 

ANSI/ESD S4.1

Resistance Accuracy

(@ 23ºC, 40% R.H.)

Resistance measurements 

within ±10% (±20% accuracy 

for 1 x 10

12

 ohms and 

greater), complies with 

ANSI/ESD S4.1. Under load 

voltages of 10 Volts ±5% 

and 100 Volts ±5% exceeds 

requirements of ANSI/ESD 

S4.1

Temperature Accuracy ±10%
Relative Humidity 

Accuracy

±10 integers

Power Supply

4 AA alkaline batteries

Battery Life

Approximately 1,500 

measurements

Display

OLED, 2.7" diagonal, 128 x 

64 pixel resolution

Memory Capacity

100 measurements

Operating Temperature 41ºF to 85ºF (5ºC to 30ºC)
Environmental 

Requirements

Indoor use only at altitudes 

less than 6500 ft. (2 km)
Maximum relative humidity of 

80% up to 85°F (30°C) 

Dimensions

(meter)

3.94" x 8.27" x 1.26"

(100 mm x 210 mm x 32 mm)

Dimensions

(carrying case)

15.0" x 14.5" x 3.5"

(381 mm x 368 mm x 89 mm)

Weight

(meter with batteries)

0.9 lbs (0.4 kg)

Weight

(populated carrying 

case)

13.0 lbs (5.9 kg)

Country of Origin

United States of America

Limited Warranty, Warranty Exclusions, Limit of 

Liability and RMA Request Instructions

See the SCS Warranty - 

StaticControl.com/Limited-Warranty.aspx

Summary of Contents for 770760

Page 1: ...Materials Floor Materials Foot Grounders ESD SP9 2 Foot Grounders Resistive Characterization Garments ANSI ESD STM2 1 Garments Seating ANSI ESD STM12 1 Seating Resistive Measurement Floor Footwear AN...

Page 2: ...Electrode 770766 Measurement Location Labels 25 Pack 770007 Concentric Ring Probe 770757 Two Point Resistance Probe 770767 5 Pound Electrodes Packaging 770760 Resistance Pro Meter Kit 1 Resistance Pro...

Page 3: ...voltage and resistance measurement D Power Switch Slide the switch to the left to power the meter OFF Slide the switch to the right to power the meter ON E Black Pushbuttons Each black pushbutton corr...

Page 4: ...ll memory Erases all stored measurement transactions saved in the meter s memory R S Figure 7 Settings menu R Memory Slot Number Indicates the memory slot number S Resistance Measurement Indicates the...

Page 5: ...urthest convenient point on the surface 5 Push the red pushbutton to perform a measurement Should the 15 second electrification period appear it may be bypassed by pushing the red pushbutton a second...

Page 6: ...nd electrodes conductive pads are dry prior to use See specific product test standards for test lab specimen cleaning instructions Per ANSI ESD S4 1 Worksurfaces The test specimens and electrodes shal...

Page 7: ...3 9 C 1 7 C at 40 to 60 relative humidity The meter needs to stay at a temperature of 75 F 3 F 23 9 C 1 7 C for approximately 1 hour for proper readings The meter cannot be normalized inside objects e...

Page 8: ...e Humidity Accuracy 10 integers Power Supply 4 AA alkaline batteries Battery Life Approximately 1 500 measurements Display OLED 2 7 diagonal 128 x 64 pixel resolution Memory Capacity 100 measurements...

Reviews: