background image

SCS 

- 926 JR Industrial Drive, Sanford, NC 27332

East: (919) 718-0000 | West: (909) 627-9634 • Website: 

StaticControl.com

TB-9091

 Page 1 of 8

© 2019 DESCO INDUSTRIES INC

Employee Owned

Resistance Pro Meter Kit

Installation, Operation and Maintenance

Description

The SCS 

770760

 Resistance Pro Meter Kit is 

an instrument designed to measure resistance 

point-to-point (Rtt) or surface to ground (Rtg).
Its test functions include:

•  Resistance measurement accuracy of ±10% 

(±20% accuracy for 1 x 10

12

 ohms and greater)

•  Resistance range of <1 x 10

3

 ohms to >1 x 10

12

 

ohms

•  Under load voltages of 10 and 100 volts ±5%

•  Electrification period of approximately 15 seconds
The Resistance Pro Meter also measures ambient 

temperature and relative humidity. Up to 100 

measurements may be stored and recalled from the 

meter's internal memory. This includes the resistance 

value, temperature, relative humidity and test voltage at 

the time of the measurement.

April 2019

The Surface Resistance Meter is referenced and 

designed to be used to make measurements in 

accordance with the test procedures in: 
•  Compliance Verification - ESD TR53 - Resistance  

Measurements

•  Worksurfaces - ANSI/ESD S4.1 Worksurfaces

•  Floors - ANSI/ESD S7.1- Resistive Characterization 

of Materials Floor Materials

•  Foot Grounders - ESD SP9.2 - Foot Grounders 

Resistive Characterization

•  Garments - ANSI/ESD STM2.1 Garments 

Seating - ANSI/ESD STM12.1- Seating - Resistive 

Measurement

•  Floor/Footwear - ANSI/ESD STM97.1 - Floor 

Materials and Footwear- Resistance Measurement 

in Combination with a Person

“A Compliance Verification Plan shall be established 

to ensure the Organization’s fulfillment of the technical 

requirements of the ESD Control Program Plan. Process 

monitoring (measurements) shall be conducted in 

accordance with a Compliance Verification Plan that 

identifies the technical requirements to be verified, the 

measurement limits and the frequency at which those 

verifications shall occur. The Compliance Verification 

Plan shall document the test methods and equipment 

used for process monitoring and measurements. If the 

test methods used by the Organization differ from any 

of the standards referenced in this document, then 

there must be a tailoring statement that is documented 

as part of the ESD Control Program Plan. Compliance 

verification records shall be established and maintained 

to provide evidence of conformity to the technical 

requirements. The test equipment selected shall be 

capable of making the measurements defined in the 

Compliance Verification Plan.” (ANSI/ESD S20.20 

section 7.3)

Made in the

United States of America

Figure 1. SCS Resistance Pro Meter Kit

 USER GUIDE TB-9091

Summary of Contents for 770760

Page 1: ...Materials Floor Materials Foot Grounders ESD SP9 2 Foot Grounders Resistive Characterization Garments ANSI ESD STM2 1 Garments Seating ANSI ESD STM12 1 Seating Resistive Measurement Floor Footwear AN...

Page 2: ...Electrode 770766 Measurement Location Labels 25 Pack 770007 Concentric Ring Probe 770757 Two Point Resistance Probe 770767 5 Pound Electrodes Packaging 770760 Resistance Pro Meter Kit 1 Resistance Pro...

Page 3: ...voltage and resistance measurement D Power Switch Slide the switch to the left to power the meter OFF Slide the switch to the right to power the meter ON E Black Pushbuttons Each black pushbutton corr...

Page 4: ...ll memory Erases all stored measurement transactions saved in the meter s memory R S Figure 7 Settings menu R Memory Slot Number Indicates the memory slot number S Resistance Measurement Indicates the...

Page 5: ...urthest convenient point on the surface 5 Push the red pushbutton to perform a measurement Should the 15 second electrification period appear it may be bypassed by pushing the red pushbutton a second...

Page 6: ...nd electrodes conductive pads are dry prior to use See specific product test standards for test lab specimen cleaning instructions Per ANSI ESD S4 1 Worksurfaces The test specimens and electrodes shal...

Page 7: ...3 9 C 1 7 C at 40 to 60 relative humidity The meter needs to stay at a temperature of 75 F 3 F 23 9 C 1 7 C for approximately 1 hour for proper readings The meter cannot be normalized inside objects e...

Page 8: ...e Humidity Accuracy 10 integers Power Supply 4 AA alkaline batteries Battery Life Approximately 1 500 measurements Display OLED 2 7 diagonal 128 x 64 pixel resolution Memory Capacity 100 measurements...

Reviews: