Description

The SCS 724 Plus Workstation Monitor continuously 

monitors the path-to-ground integrity and body voltage 

of two operators, as well as the path-to-ground integrity 

for one conductive or dissipative worksurface. The 

724 Plus Workstation Monitor eliminates the need for 

periodic testing and record keeping of wrist straps.
The 724 Plus Workstation Monitor is designed with 

digital signal processing technology for true continuous 

monitoring (versus pulsed or intermittent) of wrist strap 

functionality (path-to-ground and presence of two 1 

megohm resistors) and operator safety according 

to accepted industry standards. It is unaffected 

by capacitance variations from personnel or the 

environment. Digital signal processing technology uses 

dual-wire wrist straps to apply a low test voltage of 

0.40 V onto the operator for the handling of sensitive 

components.
The 724 Plus Workstation Monitor features operator 

body voltage detection. It will alarm if the operator 

generates or comes in contact with voltage that would 

be dangerous to an ESD susceptible item. Each 724 

Plus Workstation Monitor is calibrated with accepted 

procedures and standards traceable to the National 

Institute of Standards and Technology (NIST) and 

includes a certificate of calibration.
ANSI/ESD S20.20 section 7.3 states “Compliance 

verification records shall be established and maintained 

to provide evidence of conformity to the technical 

requirements.” Per ANSI/ESD S1.1 Annex A.3 Daily 

(wrist strap system) testing may be omitted if constant 

monitoring used.” Per ESD Handbook ESD TR 20.20 

section 5.3.2.4.4 “Typical Test programs recommend 

that wrist straps that are used daily should be tested 

daily. However, if the products that are being produced 

are of such value that knowledge of a continuous, 

reliable ground is needed, and then continuous 

monitoring should be considered or even required.”

The 724 Plus Workstation Monitor and its accessories 

are available as the following item numbers:

Item

Description

770724

724 Plus Workstation Monitor

770732

Operator Remote, Dual

770733

Operator Remote, Workstation 2

770735

Replacement Nylong Plug for 770733 

Operator Remote, Pack of 20

770065

Verification Tester

CTA212

Power Adapter, 100-240 VAC Input, 12 VDC 

1.5 A Output, All Plugs

Packaging

770724

 724 Plus Workstation Monitor

1  724 Plus Workstation Monitor

1  Dual Operator Remote

1  Operator Remote Cable

1  Mat Monitor Cord (White)

1  Monitor Ground Cord (Green and Yellow)

1  Countersunk Washer

1  Flat Head Screw, 6-32 x 1/4"

4  Pan Head Screw, #6 x 3/8"

1  Power Adapter, 12 VDC, with interchangeable plugs

  (North America, UK/Asia, Europe)

770732

 Dual Operator Remote

1  Dual Operator Remote

1  Operator Remote Cable

2  Pan Head Screw, #6 x 3/8"

770733

 Workstation 2 Operator Remote

1  Workstation 2 Operator Remote

1  Operator Remote Cable

2  Pan Head Screw, #6 x 3/8"

1  Black Nylon Plug

724 Plus Workstation Monitor

Installation, Operation and Maintenance

Made in the

United States of America

 USER GUIDE TB-9098

Figure 1. SCS 724 Plus Workstation Monitor

U.S. Patents 6,930,612; 9,983,251

Summary of Contents for 724 Plus

Page 1: ...rds shall be established and maintained to provide evidence of conformity to the technical requirements Per ANSI ESD S1 1 Annex A 3 Daily wrist strap system testing may be omitted if constant monitori...

Page 2: ...wer Jack Connect the included 12 VDC power adapter here E Set Switch Toggles the monitor s settings for the audible alarm mat monitor circuit and operator high test limit Feature Procedure Enable Disa...

Page 3: ...or will alarm should the operator remote cable disconnect from this connector Workstation 2 Operator Remote Figure 4 Workstation 2 Operator Remote features and components A FRONT BACK C B D A Power LE...

Page 4: ...1 8 Insert the tinned termination of the ground cord into the ground terminal located on the back of the 724 Plus Workstation Monitor Use a small screwdriver to secure the wire to the terminal block...

Page 5: ...nitor from power 2 Determine the mounting location of the Workstation 2 Operator Remote Its jack should be accessible to the second operator Locate it within reach of the included operator remote cabl...

Page 6: ...tor 1 Fit the wristband snugly onto the wrist 2 Snap the wrist cord to the wristband 3 Plug the wrist cord into one of the operator jacks on the Dual Operator Remote The corresponding operator LED wil...

Page 7: ...240VAC 50 60 Hz Output 12 VDC 1 5 A Output Plug Polarization Center Positive Output Plug 5 5 mm O D x 2 1 mm I D x 9 5 mm L Operator Wrist Strap Dual Wire Amount Monitored 2 Resistance Limit 1 5 mego...

Reviews: