D7- Testing and checking
Make sure the general safety precaution «WARNING» has been carefully observed :
• Release the gearmotor with the proper release key.
• Make sure the gate can be moved manually during opening and closing phases with a force of max 390N
(40 kg approx).
• Lock the gearmotor.
• Using the key selector switch, push button device or the radio transmitter, test the opening, closing and stopping
of the gate and make sure the gate is in the intended direction.
• Check the devices one by one (photocells, blinker, key selector, etc.) and confirm the control unit recognizes
each device.
Photocellule 1
Photocells
D8- Recognition of LED
LED indications
Descriptions
LED 1 Photocells
The LED1 turns on, when there is an obstacle between the photocells or an aligning
defect or a connection defect (Be careful, function H must be activated with a connected
photocell on PH1).
LED 2 Photocells
The LED2 turns on, when there is an obstacle between the photocells or an aligning
defect or a connection defect (Be careful, function J must be activated with a connected
photocell on PH2).
E- TECHNICAL FEATURES
E- TECHNICAL FEATURES
Remote controls
Channels
4
Frequency - Maximum transmitted power
433.92 MHz - power < 10mW
Power supply
1 batterie lithium CR2032 included
Security
rolling code technology
Summary of Contents for kit HWay 24V
Page 9: ...9 FR C5 Installation et raccordement Branchement de l alimentation 230 volts Non utilisé ...
Page 30: ...30 EN C5 Installing 230V connection switch power supply Not used ...
Page 51: ...51 IT C5 Impianto Collegamento dell alimentazione 230 volt Non usato ...
Page 72: ...72 ES C5 Instalación y conexión Cableado de la alimentación 230 volts No utilizado ...
Page 86: ......
Page 87: ......