DLY BUILT
DOOR OPENING MECHANISM - STANDARD FITTING
The InterFit Vertical Up Lift comes with an integrated door opening
solution which works as follows:
STEP 1.
Bolted to the LH side of the lifter up-right is a full height door guide
with a nylon runner wheel mounted at the top, which pushes open the
door on the upward travel.
STEP 2.
You should mount the panel unit so that it is level with the top of
this nylon runner wheel - you may need to trim the door guide arm to
suit, making sure it still goes all the way to the bottom of the unit, so
the door does not get trapped under it when in the up position. You can
slide the door guide arm up or down by loosening the channel bolts
accordingly.
STEP 3.
The unit is supplied with 2 off (White & Black) nylon wear pads that are designed to be fitted
and to protect the underside of your opening door and glide along the edge of the door guide. Two
colours supplied for door colour matching purposes.
STEP 4.
It is recommended that the hinge or pivot point for the door be 50mm back from the outer
edge of the door guide arm, as this will stop the door from over tilting and falling back away from
the mechanism.
STEP 5.
If you don’t have enough room for the recommended 50mm pivot point then you will require
a spring tension system to pull the door against the lifting unit and stop the door overbalancing - a
solution is available from Screen Technics, please contact during office hours to enquire.
Keep in mind the door weight / panel weight combination must be within published specifications for
maximum unit capacity (marble or granite tops may be an issue). See design sheet for details.
Continued Over.../
INSTRUCTIONS -
INTERFIT
Vertical Up Lift
•
•
•
•
•
FIXED DOOR MOUNTING PLATE - OPTIONAL EXTRA FITTING
Enables a cut piece of cabinet or bench top (within
specified weight restrictions) to be flush mounted to the
top of the Lifting unit
•
Enables a cut piece of cabinet or bench top (within
specified weight restrictions) to be flush mounted to
the top of the Lifting unit.
•
T Section mounting plate is adjustable for height
utilising the side locking Allen Key bolts.
•
Ensure that no obstructions exist with this style of
door fitting as it will close flush with exiting cabinet
and possibly damage any items that get in the way.
•
We recommend a non latching switch that
necessitates someone to keep pushing the control
switch until the unit is fully closed as a safety measure.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
GENERAL ADVICE
•
The up and down stop positions are set using the limit adjustment switches and are set at the
factory to allow maximum travel distance - due care must be taken if adjusting these limit
switches as any damage caused to the unit will void any warranty.
•
The unit requires no maintenance throughout it’s life, although an inspection should be carried
out approximately every l8months.
•
Please ensure any cables are safely away from any moving parts.
•
When reversing direction of the travel in this unit a minimum delay of half a second is required
to be programmed in to prevent instant reversals.