Screen Service
SDT 200UB – SDT 500UB ARK-1 ATSC
Operations
July, 2009
v 1.0
Page 3 - 27
OID
Name
R\W Description
1.3.6.1.4.1.21678.186.5.4.2 ark1atsc_NotUsed
1.3.6.1.4.1.21678.186.5.5 ark1atsc_OutputMonitor
1.3.6.1.4.1.21678.186.5.5.1 ark1atsc_Monitor_FwdPowerDbm
R
Forward power [dBm x 10] indicator
1.3.6.1.4.1.21678.186.5.5.2 ark1atsc_Monitor_AgcMode
R
AGC mode status 0: analog 1: digital
1.3.6.1.4.1.21678.186.5.5.3 ark1atsc_Monitor_AgcOn
R
Auto AGC status 0: off 1: on
1.3.6.1.4.1.21678.186.6 ark1atsc_HW_monitor
1.3.6.1.4.1.21678.186.6.1 ark1atsc_HW_monitor_RflPowerDbm
R
Reflex power [dBm x 10]
1.3.6.1.4.1.21678.186.6.2 ark1atsc_HW_monitor_Amplifier
R
Amplifier status 0: on 1: off 2: restart 3:
stand by off 4: GPS off 5: init 6: alarm off 7:
rf off 8: opto off 9: change mode
1.3.6.1.4.1.21678.186.6.3 ark1atsc_HW_monitor_CurrentOut
R
Current indicator (mA)
1.3.6.1.4.1.21678.186.6.4 ark1atsc_HW_monitor_PowerSupply
R
Voltage indicator (mV): 28V for 20W and 50W
versions, and 42V for 200W version
1.3.6.1.4.1.21678.186.6.5 ark1atsc_HW_monitor_FanPulse
1.3.6.1.4.1.21678.186.6.5.1 ark1atsc_FanSpeed1
R
FAN 1 speed (rpm)
1.3.6.1.4.1.21678.186.6.5.2 ark1atsc_FanSpeed2
R
FAN 2 speed (rpm)
1.3.6.1.4.1.21678.186.6.5.3 ark1atsc_FanSpeed3
R
FAN 3 speed (rpm) - only for 200W version
1.3.6.1.4.1.21678.186.6.5.4 ark1atsc_FanSpeed4
R
FAN 4 speed (rpm) - only for 200W version
1.3.6.1.4.1.21678.186.6.6 ark1atsc_HW_monitor_Temperature
1.3.6.1.4.1.21678.186.6.6.1 ark1atsc_TemperatureCase
R
Case temperature
1.3.6.1.4.1.21678.186.6.6.2 ark1atsc_TemperaturePsu
R
PSU temperature
1.3.6.1.4.1.21678.186.6.6.3 ark1atsc_TemperatureCase2
R
Case temperature 2 (only in SDTX 200 version)
1.3.6.1.4.1.21678.186.6.7 ark1atsc_HW_monitor_Relays
1.3.6.1.4.1.21678.186.6.7.1 ark1atsc_Relay0Status
R
Relay 0 status 0: on 1: off
1.3.6.1.4.1.21678.186.6.7.2 ark1atsc_Relay1Status
R
Relay 1 status 0: on 1: off
1.3.6.1.4.1.21678.186.6.7.3 ark1atsc_Relay2Status
R
Relay 2 status 0: on 1: off
1.3.6.1.4.1.21678.186.6.7.4 ark1atsc_Relay3Status
R
Relay 3 status 0: on 1: off
1.3.6.1.4.1.21678.186.6.8 ark1atsc_HW_monitor_Opto
1.3.6.1.4.1.21678.186.6.8.1 ark1atsc_Opto0Status
R
Opto 0 status (RF Off): if closed the output RF is
switch off 0: closed 1: opened
1.3.6.1.4.1.21678.186.6.8.2 ark1atsc_Opto1Status
R
Opto 1 status (Mode Switch): if closed Mode B,
otherwise Mode A 0: closed 1: opened
1.3.6.1.4.1.21678.186.6.8.3 ark1atsc_Opto2Status
R
Opto 2 status (Retry, only in 200 watt version) 0:
closed 1: opened
1.3.6.1.4.1.21678.186.6.8.4 ark1atsc_Opto3Status
R
Opto 3 status (Stand-by): if closed the device is
put on stand-by 0: closed 1: opened
1.3.6.1.4.1.21678.186.6.9 ark1atsc_HW_monitor_PowerSupply24V
R
24V voltage indicator (mV), only in 200 watt
version