7.6
Other Inputs/Outputs
The power button input is only required when the manual start power mode
is configured (Factory option). In this case temporarily activating this input by
connecting it to ground will start the unit if switched off and shut down the
unit when active. Activating the input for more than four seconds will result in
an immediate power off. Internally this input is pulled up to 3.3V via a
10kOhm resistor.
A semiconductor relay output provides the same information as the front
power LED. The “contacts” are electrically isolated from the power input and
from the other system signals. The switching capabilities are 50V, 0.2A.
A typical application of this output is:
The 12V Power Output can be used to supply external equipment. It allows a
maximum load of 1.2A.