Page 19 of 36
P/N 595225-01 Rev C 4/12
STORAGE OF THE OPTIONAL EMERGENCY FACEPIECE AND
BREATHING REGULATOR
1. To store the optional Emergency facepiece and Emergency breathing regula-
tor:
a) Fit the head harness of the facepiece inside the facepiece.
b) Coil the regulator hose around the regulator and fit inside the facepiece
as shown in FIGURE 20.
c) Place the facepiece and regulator into the accessory storage compart-
ment as shown in FIGURE 21.
2. To store the optional Emergency facepiece and Emergency breathing regula-
tor
connected
to the LOW pressure supply hose:
a) Prepare the facepiece and regulator as stated above.
b) Connect the regulator male quick disconnect to the female quick discon-
nect on the dual manifold.
c) Place the facepiece and regulator into the accessory storage compart-
ment with the LOW pressure supply hose fitting across the notch in the
accessory compartment as shown in FIGURE 22.
Proceed to the FINAL PREPARATION section of this instruction.
FIGURE 20
FIGURE 22
FIGURE 21
PREPARATION FOR USE
CONTINUED ON NEXT PAGE...