module will enter pairing mode.  Once paired, the 
module will connect to Onvation. 

2.  Alternately a factory reset may be performed: 

If the magnet is held for a long period of time, all LEDs 
will turn on.  This means a factory reset of the module is 
performed.  All parameters are erased.  The module 
enters a “Dispenser Detect” state where a dispense 
must be performed after a factory reset. 

 

PAN Modul e Light  Pattern s 

Status 

The 2 module board options function in consistent ways. 

There are 3 LEDs on installed on the board.  Red, Green, and Blue.  These LEDs are turned on with specific patterns 
to indicate the board’s status. 

State: Un config ure d – Waiting for Dis pens er  

 

In this state, the module has not yet been configured for a specific dispenser type.  It will blink 1X per second until the 
dispenser type is determined. 

The module determines dispenser type when a dispense is performed.  The Dispense (EOS) signal is toggled, and 
then status is sent to the module.  Once the dispenser type is determined, it is saved and is only cleared upon a 
factory reset. 

IMPORTANT: 

Once installed and powered in a dispenser, the module should not be left indefinitely in this state- as it 

will consume significantly more power than if it transitions out of this mode. 

State: Disp ens er  Type Co nfirmation  

   OR   

   OR    

 

At startup, the dispenser enters the 

dispenser type confirmation 

state once it determines the dispenser type 

configuration for the module.  The LED is turned on 

solid

 for a 1.5 second period to confirm the dispenser type.  After 

the module enters this state, it will query the dispenser for its state, if possible, and then will begin initially advertising. 

 

Summary of Contents for PURELL ONVATION CXR

Page 1: ...s enter them into the ONVATION Installer App 4 Install the Dispenser per the Dispenser Installation Guidelines 5 Plug the PAN Module into the SMARTLINK GOJO Industries Inc All Rights Reserved ONVATION...

Page 2: ...ower source 7 If space is available attach the PAN module to the CXR pumphouse by the module mount If space is not available the module can be affixed via screw to the wall 8 Once the module is instal...

Page 3: ...your hand under the spout to dispense 4 activations are required at startup to dispense foam soap Wi Fi BLE Provisioning Exceptions Issue Code Module Not Configured All 3 LEDs on module will blink unt...

Page 4: ...not yet been configured for a specific dispenser type It will blink 1X per second until the dispenser type is determined The module determines dispenser type when a dispense is performed The Dispense...

Page 5: ...d advertising interval before advertising again In Production Firmware this LED sequence is disabled for advertising without pairing When pairing this LED sequence is enabled State Connected In the co...

Page 6: ...e that it no longer has bond information and will automatically disconnect before parameters are sent The module will then re attempt a connection attempt 1 minute later and this time the connection w...

Page 7: ...not installed and used in accordance with the instruction manual ma interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in wh...

Reviews: