Page 12 of 36
P/N 595289-01 Rev B 5/15
PROGRAMMING A UNIT WITH AN RFID TAG
SCOTT recommends re-programming with the RFID card in accordance with your
organization's procedures to assure that the user's unique ID number is in use at
all times. To program the identification of a SEMS II Portable unit with an RFID Tag,
proceed as follows:
1. Verify that the air cylinder is closed and there is no residual air in the system.
2. Verify that the electronics have been inactive for at lease thirty (30) seconds.
3. On the Control Console, hold down the GRAY (Withdraw) button until the ID light
goes on. Release the button.
4. Within ten (10) seconds, hold your SEMS II ID Tag against the back of the Control
Console labeled "SCAN ID TAGS HERE."
5. To indicate the programming has been successful, the ID light will flash three (3)
times slowly then go out.
6. When performing the REGULAR OPERATIONAL INSPECTION of the SEMS
II Accountability System, verify that the correct ID appears on the Base Station
display.
NOTE
ONCE THE RESPIRATOR HAS BEEN PRESSURIZED FOR USE, THE ID CANNOT
BE CHANGED. THE RESPIRATOR MUST BE SHUT DOWN AND THERE MUST
BE NO RESIDUAL AIR PRESSURE LEFT IN THE SYSTEM TO CHANGE THE ID.
To manually remove the programmed RFID card number, verify that the air cylinder is
closed, there is no residual air in the system, and the PASS is in the off state. Press
and hold the YELLOW RESET Button for eight (8) seconds. During reset, the red lights
on the PASS console will alternately flash and SEMS II Distress Alarm Pass device
will attempt to interface with Data Logger computer.
Additionally, the unit will automatically return to the default ID number:
– if the battery cover is opened and/or the batteries are removed,
OR
– after twenty-four (24) hours.
PRESSING THE GRAY (WITHDRAW)
BUTTON
PROGRAMMING THE USER ID WITH THE RFID TAG
ID LIGHT WILL FLASH 3
TIMES SLOWLY TO INDICATE
SUCCESSFUL PROGRAM
OPERATION AND USE OF ACCOUNTABILITY SYSTEM
CONTINUED...