1. The bin control uses devices that sense light,
therefore they must be kept clean enough so that
they can "see". At least twice a year, remove the
bin control sensors from the base of the ice chute,
and wipe the inside clean, as illustrated.
2. The ice machine senses water level by a probe
located in the water reservoir. At least twice a
year, the probe should be removed from the
reservoir, and the tip wiped clean of mineral
build-up.
3. The bearing in the breaker should also be
checked at least two times per year.
A. Check the bearing by:
••
removing the ice chute cover
••
unscrewing the ice sweep
••
removing the water shed
••
unscrewing the breaker cover.
••
unscrewing the auger stud
Inspect the assembly, looking for wear.
See Removal and Replacement to replace
bearing or seals. Reverse to reassemble.
4. Check and tighten all bolts and screws.
CLEAN THE
WATER LEVEL
PROBE
PULL UP TO
REMOVE PROBE
RESERVOIR
///////////////////////////////////////////
CAUTION: THE TIP IS
MADE OF GLASS
//////////////////////////////////////////
ICE LEVEL SENSORS:
SLIDE UP TO REMOVE
CLEAN THE
LIGHT
SENSORS
MAINTENANCE AND CLEANING
ICE SWEEP
BREAKER
COVER
Moving Parts Hazard.
Rotating Auger can
cause personal injury.
Disconnect electrical
power before beginning.
NSE650
June 1994
Page 16