FOR THE ELECTRICIAN

CONFORM TO ALL APPLICABLE CODES

The electrical power to the unit is supplied
through the junction box at the rear of the
machine.
Check the nameplate (located on the back
panel) for the voltage requirements, and for
the minimum circuit ampacity.  The machine
requires a solid chassis to earth ground wire.
The ice maker should be connected to its own
electrical circuit so it would be individually
fused. Voltage variation must remain within
design limitations, even under starting
conditions.

Electrically the remote condenser fan motor is
connected to the icemaker at the contactor
terminals for the compressor and the fan
motor operates whenever the compressor
operates.
Electrical connections are made at the
junction box at the back of the icemaker and
at the junction box on the remote condenser.
The remote condenser must be wired to the
icemaker in accordance with local and
national electrical codes with a minimum of 18
Awg. wire with an ground bonding wire
connected to the ground screws provided in
both the condenser and machine field wiring
boxes.  All outdoor wiring must be in rainproof
conduit.
All external wiring must conform to
national, state, and local electrical codes.
The use of a licensed electrician is
required to perform the electrical
installation.

TERMINAL STRIP

FOR REMOTE

CONDESNER

ICEMAKER

JUNCTION BOX

POWER

SUPPLY

GROUND

THE

CHASSIS

RAIN PROOF

CONDUIT

NM1850R

September, 1992

Page 10

Summary of Contents for NM1850R

Page 1: ...oring ice and water level a thermostatic expansion valve and R 502 as the refrigerant TABLE OF CONTENTS For the Installer Specifications 2 Location 5 Remote Condenser 6 For the Plumber 9 For the Elect...

Page 2: ...18 8 There are two separate ice making and refrigeration systems in this model The liquid and discharge lines from each system must go to separate circuits in one remote condenser RC1052 Minimum Circu...

Page 3: ...Check with a water treatment specialist for a water test and recommendations regarding filters and treatment 2 In most cases the water used to make ice should be filtered or treated depending upon th...

Page 4: ...RT 625 Precharged line set 25 R 502 2 required Or RT 640 Precharged line set 40 R 502 2 required DIMENSIONS H X W X D MODEL USE WITH MINIMUM CIRC AMPACITY BASIC ELECTRICAL RC1052 27 8 X 22 X 37 94 1 N...

Page 5: ...ling later Return the bin to the upright position remove paper covering the bin gasket Install the bin top according to the directions with the bin top Note Do not push bin into position but lift it t...

Page 6: ...s 1 Each set of precharged refrigerant lines either 25 foot or 40 foot consists of a 3 8 inch diameter liquid line and a 1 2 inch diameter discharge line Both ends of each line have quick connect coup...

Page 7: ...n resistance is felt 4 Using a marker or pen mark a line lengthwise from the coupling union nut to the bulkhead Then tighten the coupling and additional 1 4 turn As the nut turns the line will show wh...

Page 8: ...STALLER Location REMOTE CONDENSER EXCESS PRECHARGED TUBING INSIDE BUIDLING ICEMAKER SERVICE ACCESS SERVICE ACCESS SIDE AND BACK ROOF CUTAWAY WALL CUTAWAY CONTACT ROOFING CONTRACTOR NM1850R September 1...

Page 9: ...gravity type and 1 4 inch per foot fall is an acceptable pitch for the drain tubing There should be a vent at the highest point of the drain line and the ideal drain receptacle would be a trapped and...

Page 10: ...he compressor and the fan motor operates whenever the compressor operates Electrical connections are made at the junction box at the back of the icemaker and at the junction box on the remote condense...

Page 11: ...PRECHARGED REFRIGERANT TUBING A typical installation should generally appear as illustrated below The remote condenser must be located above the icemaker and the precharged lines installed per the ins...

Page 12: ...pressure a minimum of 20 psig 7 Has the machine been secured to the bin 8 Is there a water shut off valve installed near the machine 9 Is the remote condenser installed per local building codes and i...

Page 13: ...The electrical start up sequence is now on automatic A There should be a short 15 second delay before the gearmotor starts B After the gearmotor starts the liquid line valve will open the low pressur...

Page 14: ...e Ice Discharge Chute Directs the ice produced by the evaporator into the storage bin Ice Level Sensor An electronic eye it senses the presence of ice in the bottom of the ice discharge chute Operates...

Page 15: ...ircuit board Pump Down Control An automatic reset pressure switch connected to the low side of the refrigeration system Controls the compressor Potential Relay The compressor start relay On Off Switch...

Page 16: ...15 seconds bin full At that point the bin empty light goes out and the machine shuts down Shut Down consists of The liquid line solenoid closes lowering the suction pressure The pump down control open...

Page 17: ...he float valve The water them goes out the bottom of the reservoir tanks to the bottom of the evaporators Reservoir overflow or evaporator condensation is combined into a common drain line and routed...

Page 18: ...vaporator warmer evaporators get more refrigerant and colder evaporators get less At the evaporator the refrigerant enters an area of relatively low pressure where it can easily boil off or evaporate...

Page 19: ...h a small amount of discharge gas going into the receiver to maintain pressure until the head pressure is built back up to the rated gauge pressure of 220 psig At that pressure the valve opens up the...

Page 20: ...is stopped by the closed liquid line valve This action forces the refrigerant into the receiver and keeps it out of the compressor The pump down continues until the low pressure control turns the com...

Page 21: ...f swallowed DO NOT induce vomiting Give large amounts of water or milk Call Physician immediately In case of external contact flush with water KEEP OUT OF THE REACH OF CHILDREN 7 Prepare the cleaning...

Page 22: ...times per year Check the breaker bearing by removing the ice chute cover unscrewing the ice sweep removing the water shed unscrewing the breaker cover left hand thread unscrewing the auger stud Inspec...

Page 23: ...t For more information on removal and replacement of these parts see REMOVAL AND REPLACEMENT Shut off water and electrical supply 1 To remove the auger remove the front and top panels 2 Remove 3 hex s...

Page 24: ...intaining a head pressure above 220 psig If the unit has the correct charge and the condenser is clean and the refrigerant lines are not kinked or twisted and the condenser is not overheated by extern...

Page 25: ...lace the circuit board If the bin full light on the tester is ON move the tester switch to bin empty the light on the tester should go OFF and the bin empty light on the circuit board should go ON If...

Page 26: ...eplace in the machine b Check for low charge add some refrigerant if the unit begins to operate normal low side pressure being about 30 psig stop and look for a leak repair replace the drier evacuate...

Page 27: ...restricted defective or not adjusted properly If needed replace the TXV evacuate and recharge per nameplate 4 Check the insulation on the evaporator It should be dry with no wet spots or frost If the...

Page 28: ...aker 8 Reverse to reassemble BIN CONTROLS Ice Level Sensors 1 Disconnect electrical power 2 Remove front panel 3 Remove control box cover 4 Locate ice chute at the base of the chute in front of and be...

Page 29: ...g breaker to evaporator d Lift up and remove breaker bearing assembly from auger evaporator 6 Service the bearing Check for rust rough spots and damage a The bearing is pressed into the breaker to rem...

Page 30: ...stainless breaker cover from breaker left hand threads b Unscrew auger stud from top of auger c Unscrew 4 allen head cap screws holding breaker to evaporator d Lift up on breaker to remove from auger...

Page 31: ...ater seal down against it 3 The part of the water seal that rotates with the auger must also be replaced Remove the old part from the auger and clean the mounting area 4 Place a small bead of food gra...

Page 32: ...e that the number of shims indicated on the gear case cover is in place between the gearcase cover and the drip pan gasket Torque the bolts to 110 inch pounds 2 Lower the auger into the evaporator bar...

Page 33: ...INGS GASKET GEARCASE DRIVE MOTOR BEARING SEAL WATER SHED SEAL REMOVAL AND REPLACEMENT Gearmotor Assembly WARNING Disconnect Electrical Power Before Begining Note There are two gearmotors in each NM185...

Page 34: ...overfill Note The gears and bearings are available only as pressed together sets D After replacing parts as required if any reassemble the gearcase The two smaller gears and the oil should be in the...

Page 35: ...that the ice level sensors are properly aligned clean and not obstructed use the tester as follows Bin Control Note All testing is done with the electrical power on the master switch on and all reset...

Page 36: ...replace the circuit board b Move the water switch on the tester to the Water position The No Water light on the board should go OFF If not replace the circuit board If the light does go off replace t...