FOR THE INSTALLER: Soda Valve Kit
Installation Instructions
Note: Carbonator and carbonated product cooling
system are not included (for 115v models only).
1. Remove cabinet top panel, front panel, and
splash panel.
2. Remove water glass filler lever from machine.
3. Remove water outlet tube from machine.
4. Remove screws and remove filler plate from the
ice maker dispenser.
5. Remove large plug from base of
icemaker-dispenser.
6. Install valve assembly in the ice machine with
two screws through the same holes that held on
the valve cover plate. Install 1-3/8" ID insulation
tube over the syrup and carbonated lines.
7. Route product lines through the hole in the base.
8. Make all required connections soda line
connections, using field supplied materials. All
lines should be insulated. A carbonated water
recirculating line is provided and recommended to
insure that high quality drinks are dispensed.
9. Install transformer in upper compartment of
icemaker-dispenser, using screws provided. It may
be necessary to pre-drill holes.
10. Route drink valve assembly electrical leads up
to the transformer.
11. Connect wire leads from the drink valves to the
24 volt output side of the transformer.
12. Locate a 115 volt continuous power source
from within the icemaker control box. Route white
and black leads from the 115 volt input side of the
transformer and connect to the 115 volt power
source.
13. Turn on power and soda equipment, check
operation and check for leaks. Adjust valves for
proper mixture.
115 VOLT
CONNECTION
SODA
LINES
SODA VALVES
TRANSFORMER
24 VOLTS
ATTACH DRINK VALVE
ASSEMBLY HERE
Electrical Shock Hazard.
Disconnect electrical
power to the icemaker -
dispenser before
beginning.
NDE550 & NDE650
April 1997