Placement

The location of the equipment should be selected 

with care. Consideration should be given to allow 

adequate space on the sides for air cooled models 

to breathe. 

Minimum clearance is 3 inches at the 

sides, none at the back and 2 inches above. The 

power outlet should be located within the length of the 

supplied power cord. 

Air cooled models in a small room require ventilation 

to exhaust the heat they produce. They also produce 

some added noise from the fan. 

Nearby infrared emitters or a window that allows 

sunlight to shine on a dispensing sensor may cause 

the unit to dispense ice or water on its own. 

Wall mount units do NOT have a drip tray, so they 

MUST be positioned over a sink to collect any 

dripping water or spilled ice.
Wall Mount

These models are designed for mounting on a wall.  

Check building wall for the strength required to 

support a machine of this weight and size. Note that 

if at least 6” of space is not left above the machine, 

cleaning and most service of the machine will require 

removal of the machine from the wall mounts. All 

utilities are to be routed thru the base. One inch of 

space is needed between the wall and the back of the 

machine.

Note: The wall must be plumb or the unit will be out of 

level front to back.

It is recommended that the wall mounting installation 

be done by an experienced contractor.

The weight of the machine when in use may exceed 

350 pounds. The unit should be mounted on a solid, 

rigid wall with proper fasteners for that type of wall 

and of adequate strength to support the weight of the 

machine when in use.

Unpack

Separate the carton from the shipping pallet. 

Important: Locate and retain the wall mounting 

brackets, they were shipped in a box on the skid 

in front of the unit.

Remove any strapping holding the cabinet to the 

pallet.
Inspect for hidden shipping damage. If any is found, 

retain carton and notify carrier for potential claim. 

Shipping damage is not covered by warranty.

Remove bolts holding machine to pallet. Use caution 

to not tip unit too far when removing bolts.
Remove the protective plastic covering the panels. 

The longer it is left on the panel, the harder it will be 

to remove it.

Set Up

It is a good idea to 

remove the front panels 

and inspect for any 

loose or rubbing parts 

prior to installation.

Panel Removal

Remove one screw at 

bottom front of upper 

front panel, swing 

bottom of panel forward 

and lift off the unit.

Twist ice and water chutes counterclockwise and pull 

down to remove.

Remove four screws from sides of splash panel, pull 

forward slightly. If needed, unplug sensor connector 

and separate panel from unit.

Pre-Start Inspection

Confirm there are no loose or rubbing parts.

Summary of Contents for HID312AW

Page 1: ...Installation and User s Manual for Meridian Ice Maker Dispensers Wall Mount Models HID312AW HID525AW and HID540AW...

Page 2: ...ny caution or warning notices They are important and provide notice of potential hazards Keep this manual for future reference If additional technical information is needed go to Scotsman s website ww...

Page 3: ...material or workmanship It does not cover maintenance corrections to installations or situations when the machine is operated in circumstances that exceed the limitations printed above Product Informa...

Page 4: ...REMOVABLE AIR FILTER ICE CHUTE WATER CHUTE 88 6 34 88 44 17 33 5 1 2 01 UTILITY CHASE 2 5 1 00 OFFSET FROM WALL 38 14 95 61 9 24 38 7 7 3 02 16 9 6 66 14 5 50 0 8 312 6 WALL MOUNT HOLES 9 7 3 80 UTILI...

Page 5: ...ET REMOVABLE AIR FILTER ICE CHUTE WATER CHUTE 5 1 2 01 UTILITY CHASE 61 9 24 38 44 17 33 88 6 34 88 38 14 95 2 5 1 00 OFFSET FROM WALL 7 7 3 02 14 5 50 16 9 6 66 40 6 16 00 0 8 312 6 WALL MOUNT HOLES...

Page 6: ...00 REMOVABLE AIR FILTER ICE CHUTE WATER CHUTE 61 9 24 38 38 14 95 103 8 40 88 44 17 33 2 5 1 00 OFFSET FROM WALL 5 1 2 01 UTILITY CHASE 7 7 3 02 14 5 50 16 9 6 66 9 7 3 80 UTILITY CHASE 17 9 7 05 0 8...

Page 7: ...t be plumb or the unit will be out of level front to back It is recommended that the wall mounting installation be done by an experienced contractor The weight of the machine when in use may exceed 35...

Page 8: ...water agency may have added for purification That can require more frequent sanitization of the equipment Connect drain tubing to the 3 4 inch FPT central drain fitting at the back of the cabinet Use...

Page 9: ...th the mounting brackets Separate the two brackets Retain the bolts and lock washers 3 Identify the location of the wall studs or other materials to be used to fasten the wall bracket to 4 Mount the w...

Page 10: ...aking process The code display will show F Air cooled models will discharge warm air out the right side water cooled models will discharge warm about 110o F water out of the condenser drain 5 Soon ice...

Page 11: ...en clear up in the glass That is normal due to air in the water and is not an indicator of any malfunction Other notes An occasional drip may be seen from the ice dispense chute This is normal and is...

Page 12: ...er Dispense Sensed glows when the water dispense sensor has been triggered Ice Dispensed Sensed glows when the ice dispense sensor has been triggered Water Dispense glows when the inlet water solenoid...

Page 13: ...ge 6 Clean the dispense chutes Use ice machine scale remover if needed to dissolve scale 7 Reverse to reassemble Insert chutes and rotate CCW until they snap into place and stop Air filter The air fil...

Page 14: ...e 9 Remove 2 thumbscrews chute cover set aside 10 Lift up and remove dispense rotor set aside 11 Mix a solution of ice machine scale remover such as Scotsman Clear 1 and potable water per the directio...

Page 15: ...the lens ice machine scale remover will be needed to wipe them clean 9 Return each sensor to a grommet push it in until it snaps into place 10 Reverse the rest of the steps to reassemble Dispensing B...

Page 16: ...8 Lift water reservoir to the top of the post and re secure with the thumb screw 9 Remove cover from water reservoir 10 Vend all ice from dispenser 11 Remove dispense bin cover 12 Remove ice discharge...

Page 17: ...not overfill bin 30 Drain sanitizer from ice making system by pulling reservoir drain hose from plug and return hose to plug when drained 31 Loosen thumb screw holding water reservoir to post and lowe...

Page 18: ...Ice Dispense light glow If yes push Dispense Ice button Does the motor activate If yes go to next row If no check for voltage at motor If no voltage replace controller If voltage at motor replace moto...

Page 19: ...ight blinking Container positioned in front of water dispense sensor for more than 24 seconds Normal controller has a time limit for dispensing Remove container Water dispense light blinking Ice dispe...

Page 20: ...SCOTSMAN ICE SYSTEMS 101 Corporate Woods Parkway Vernon Hills IL 60061 800 726 8762 17 3492 03 Rev A...

Reviews: