Scotsman FME504 Installation And User Manual Download Page 5

FOR THE INSTALLER

Location:

Install the machine be installed in a location where
it has enough space around it to be accessible for
service. A minimum of 6" must be allowed at the
back and sides for air circulation on air cooled
models. Try to avoid hot, dirty and crowded
locations. Be sure that the location for the machine
is within the environmental limitations.

Storage Bin:

Tip the storage bin on its back, using parts of the
carton to protect the exterior finish. Install the legs
into the threaded holes in the bottom of the bin.
Turn the leg levelers all the way in preparation for
leveling later. Return the bin to the upright
position, remove paper covering the bin gasket.
Note: Do not push bin into position, but lift it there.
Pushing a bin, especially one with ice in it, can
cause damage to the legs and the leg mounts.
Install the appropriate bin top on the bin, according
to the instructions for the bin top.

Ice Machine:

The machine is heavy, so the use of a mechanical
lift is recommended for lifting the machine high
enough to install on top of the bin. After the unit is
placed on the bin, line it up so it is even with the
back side. Secure the machine to the bin with the
hardware provided with the machine.
Remove the front panel and remove any shipping
blocks.
Note: When placing 2 of these machines on a
BH801 without the bin top, removal of the 2 service
panels facing each other will make future service
easier:
1. Remove the 2 top panel screws that will face
each other.
2. Remove the 2 service panels that will face each
other.
3. Add a strip of gasket, such as Scotsman part
number 19-0503-04, to the 2 base edges that will
face each other and around service panel space
on the 2 panels that will face each other.
When the 2 machines are placed on the bin, the
gaskets will seal the bin top area and the space
between the machines.

NME454, 654 & FME504, 804

January 2007

Page 4

Water Limitations:

An ice machine is a food manufacturing plant: it
takes a raw material, water, and transforms it into
a food product, ice. The purity of the water is very
important in obtaining pure ice and in maximizing
product life. This section is not intended as a
complete resource for water related questions, but
it does offer these general recommendations:
1. Check with a water treatment specialist for a
water test, and recommendations regarding filters
and treatment.
2. In most cases, the water used to make ice
should be filtered or treated, depending upon the
water.

There is no one type of water filter that is

effective in all situations.

That is why a water test is

important.

RO Water Limitation:

Water conductivity must be

no less than 35 microSiemens/cm.

Note:

Scotsman Ice Systems are designed and
manufactured with the highest regard for safety
and performance. They meet or exceed the
standards of UL, NSF, and CUL.
Scotsman assumes no liability or responsibility of
any kind for products manufactured by Scotsman
that have been altered in any way, including the
use of any part and/or other components not
specifically approved by Scotsman.
Scotsman reserves the right to make design
changes and/or improvements at any time.
Specifications and design are subject to change
without notice.

Summary of Contents for FME504

Page 1: ...Installation and User s Manual for Flake and Nugget Ice Machine Models FME504 FME804 NME454 NME654...

Page 2: ...NTENANCE Page 11 AIR COOLED MAINTENANCE Page 12 BEARING MAINTENANCE Page 13 AUGER MAINTENANCE Page 14 REMOVAL AND REPLACEMENT Bin Controls Page 15 What to Do Before Calling for Service Page 16 Note th...

Page 3: ...s designed to be installed indoors in a controlled environment Min Max Air Temperature 500 F 1000 F Water Temperature 400 F 1000 F Water Pressure 20 PSI 80 PSI Voltage for 115v model 104 126 Compared...

Page 4: ...ge 3 Bin Top Kit Required SAMPLE BIN AND MACHINE COMBINATIONS FME804 ON BH550 NME654 ON BH801 FME804 ON BH900 The Nameplate is located on the back of the machine A Serial Number Plate is located insid...

Page 5: ...the 2 service panels that will face each other 3 Add a strip of gasket such as Scotsman part number 19 0503 04 to the 2 base edges that will face each other and around service panel space on the 2 pa...

Page 6: ...E504 804 January 2007 Page 5 FOR THE INSTALLER Location TWO UNITS ON ONE BIN ALLOW ROOM FOR AIR CIRCULATION AND SERVICE ACCESS ALLOW AIR SPACE ON BOTH SIDES Airflow Notice Air flow is in the sides and...

Page 7: ...to all lines must always be above 20 PSIG and below 80 PSIG Drains Air Cooled Models Connect a drain tube to the FPT drain at the back of the cabinet the drain line is of the gravity type and inch pe...

Page 8: ...ME504 804 January 2007 Page 7 WATER COOLED AIR COOLED POWER SUPPLY FOR THE INSTALLER Final Check List 1 Is the ice system installed indoors in a location where the air and water temperatures are contr...

Page 9: ...e checked it should be 34 PSIG or 4 PSIG The suction line temperature at the compressor is normally very cold nearly to the point of frost up to the compressor body but not on it The air cooled discha...

Page 10: ...water reservoir until it is full Wait 15 minutes then switch the master switch to ON 9 As the ice maker begins to use water from the reservoir continue to add more cleaning solution to maintain a ful...

Page 11: ...ean as illustrated 2 The ice machine senses water level by a probe located in the water reservoir At least twice a year the probe should be removed from the reservoir and the tip wiped clean of minera...

Page 12: ...move the filter The filter may be cleaned or replaced B Clean the condenser the condenser may appear to be clean on the surface but it can still be clogged internally Check with a flash light from the...

Page 13: ...should rotate smoothly To remove the breaker remove the lower ice chute then take out all four allen head cap screws and pull the breaker off the auger and evaporator If the bearing only needs grease...

Page 14: ...arding water treatment For more information on removal of these parts see REMOVAL AND REPLACEMENT 1 To remove the auger remove the front and top panels 2 Push bail clamp back from the top of the chute...

Page 15: ...hrough the holes in the ice chute NME454 654 FME504 804 January 2007 Page 14 ICE CHUTE SLIDE BIN CONTROLS LEFT AND RIGHT REMOVAL AND REPLACEMENT Bin Controls RESERVOIR 1 Shut off water supply 2 Remove...

Page 16: ...SCOTSMAN ICE SYSTEMS 775 Corporate Woods Parkway Vernon Hills IL 60061 800 533 6006 www scotsman ice com 17 3154 01...

Reviews: