1. The bin control uses devices that sense light,
therefore they must be kept clean enough so that
they can "see". At least twice a year, remove the
bin control sensors from the base of the ice chute,
and wipe the inside clean, as illustrated.
2. The ice machine senses water level by a probe
located in the water reservoir. At least twice a
year, the probe should be removed from the
reservoir, and the tip wiped clean of mineral
build-up.
3. The top bearing in the breaker should also be
checked at least
two times per year
.
Check the breaker bearing by:
••
removing the ice chute cover
••
unscrewing the ice sweep
••
removing the water shed
••
unscrewing the breaker cover (left hand thread)
••
unscrewing the auger stud
Inspect the assembly, looking for wear
4. Clean the remote condenser. Use a vacuum
cleaner or coil cleaner if needed.
Do NOT use a wire brush.
5. Check and tighten all bolts and screws.
MAINTENANCE AND CLEANING
RESERVOIR
WATER LEVEL
SENSOR
//////////////////////////////////////
CAUTION: THE TIP
IS MADE OF GLASS
///////////////////////////////////////
SLIDE UP
TO REMOVE
ICE CHUTE
ICE LEVEL
SENSORS
SLIDE LEFT TO
REMOVE
ICE
SWEEP
BREAKER
COVER
These units consist of two separate ice makers; to properly clean and maintain the them, these steps
must be followed for both systems.
Disconnect electrical
power before
beginning.
NME1850R & FME2400R
January 1995
Page 21