Operational Characteristics 1800 lb system
Cycle Times @ Condenser Temp/Cabinet Temp/Water Temp in degrees F.
System Pressures @ Condenser Temp/Cabinet Temp/Water Temp in degrees F
Headmaster maintains a minimum discharge
pressure during freeze of:
·
217 PSIG + 25, -15 PSIG
CPR Valve Setting: 55 - 60 PSIG.
Note: CPR allows a maximum low side pressure at
the CP unit’s compressor. Maximum only occurs
during harvest.
Refrigerant Charge
·
288 oz
Compressor Amps
·
Single Phase - 16 to 20
·
Three Phase - 10 to 14
Batch Weight: lb. Small cube: 14 to 15. Medium
cube: 13 to 14
Discharge Pressure Cut Out Switch
·
Cuts Out at: 450 PSIG
·
Resets at: 350 PSIG
Compressor: CS24K6E
Expansion Valves: 2
Prodigy Eclipse
ä
1400, 1800, 2000
April 2006
Page 44
70/70/50
90/90/70
120/110/100
Freeze
10 to 14 minutes
12 to 16 minutes
17 to 19 minutes
Harvest
1 to 1:30 minutes
1 to 1:30 minutes
1 to 1:30 minutes
70/70/50
90/90/70
120/110/100
Suction at Ice Making Section, end of Freeze
25 to 35 PSIG
25 to 35 PSIG
25 to 35 PSIG
Suction at Ice Making Section, Harvest - Peak
80 to 100 PSIG
90 to 110 PSIG
140 to 160 PSIG
Discharge at Condensing Unit: Freeze - 5 minutes in
260 to 280 PSIG
260 to 280 PSIG
330 to 350 PSIG