EH222 E and Condensing Unit
Remote Low Side Cuber User Manual
June 2017
Page 3
Configuration
A remote low side cuber system includes two sub
systems: an ice making head and a remote air cooled
condensing unit. This manual covers the EH222 head
and the condensing units that go with it.
The ice making heads are designed for use indoors
in a controlled environment. The remote condensing
units are designed to operate outdoors. Each sub-
system has limits for power, water and temperature.
Operational Limitations:
Minimum
Maximum
Air Temp (at head) 50
o
F
100
o
F.
Air Temp (CU)
-20
o
F.
120
o
F.
Water Temp
40
o
F.
100
o
F.
Water Pressure
20 psi
80 psi
Water Conductivity 10
microSiemens/cm
any
Voltage (at head)
104
126
Voltage (CU)
198
253
CU= Condensing Unit
Do Not operate the machine in conditions beyond
these limitations. Doing so will void the warranty.
Scotsman ice systems are designed and
manufactured with the highest regard for safety and
performance. They meet or exceed common agency
standards.
Scotsman assumes no liability of responsibility of
any kind for products manufactured by Scotsman
that have been altered in any way, including the use
of any part and/or other components not specifically
approved by Scotsman.
Scotsman reserves the right to make design changes
and/or improvements at any time. Specifications and
design are subject to change without notice.
Warranty
Refer to the warranty coverage in effect when the
equipment was sold. Warranty statements are
included with each product.
Systems:
Ice making heads and condensing units have their
own model and serial numbers. They must be
combined to create a remote cuber low side system.
Notes: Voltage Codes are at the end of the model
number. Codes read Voltage/Hertz/Phase. Those
related to these products include:
-1 = 115/60/1
-3 = 208-230/60/3
-32 = 208-230/60/1
System Information
Tubing kits are required to connect the head to the
condensing unit.
Interconnecting 24 volt control wire ships with the
condensing unit.
System Size
Condensing Unit (CU)
Ice Making Head
Model
Electrical (volts/Hz/phase
Model
Electrical (volts/Hz/phase)
800
ECC0800-32E
208-230/60/1
EH222SL-1E
115/60/1
800
ECC0800-3E
208-230/60/3
same
same
1000
ECC1410-32E
208-230/60/1
same
same
1000
ECC1410-3E
208-230/60/3
same
same