Page 23
Page 23
NOTE. The ICE LEVEL CONTROL
(INFRARED SYSTEM) is independent of
the temperature however, the reliability of its
detection can be affected by external light
radiations or by any sort of dirt and scale
sediment which may deposit directly on the
light source and on the receiver.To prevent
any possible ice maker malfunction, due to
negative affection of the light detector, it is
advisable to locate the unit where it is not
reached by any direct light beam or light
radiation, also it is recommended to keep the
bin door constantly closed and to follow the
instructions for the periodical cleaning of
the light sensor elements as detailed in the
MAINTENANCE AND CLEANING PRO-
CEDURES.
Its sensivity can be adjusted by turning the IR
trimmer.
M.
Remove, if fitted, the refrigerant service
gauges and re-fit the unit service panels
previously removed.
N.
Instruct the owner/user on the general
operation of the ice machine and about the
cleaning and care it requires.