REMOVAL AND REPLACEMENT
//////////////////////////WARNING////////////////////////////
Disconnect ice machine from electrical
power before proceeding.
/////////////////////////////////////////////////////////////////////
Bin Thermostat
1. Unplug the icemaker to disconnect
electrical power.
2. Remove screws and cabinet front panel.
3. Remove screws and control box cover,
disconnect electrical wires from bin
thermostat control.
4. Dismount bin thermostat from the control
box
5. Remove rear panel.
6. Pull bin thermostat capillary line from
tube in ice storage bin. Remove complete
control from ice machine.
7. Replace with new control in reverse
order of removal.
Cube Size Control
1. Unplug the icemaker to disconnect
electrical power.
2. Remove screws and cabinet top, front,
and rear panels.
3. Pull knob from cube size control shaft.
Remove screws and control box cover to
gain access to the cube size control body.
Remove screws and dismount cube size
control from control box. Disconnect
electrical wires from cube size control.
4. At the top of the machine, unclip cube
size thermostat tube holder from
evaporator, (retain clips and tube
assembly.) Pull cube size control capillary
tube from the tube, and remove complete
cube size control from the ice maker.
5. Insert capillary tube on new thermostat
into tube holder, be sure that the end caps
are in place.
6. Reverse the removal procedures to
reinstall the cube size control. Adjust as
needed.
Refrigeration System
Any time the refrigeration system is
opened, the drier must be replaced, the
system evacuated and the exact charge
measured into the system. Any other
procedure is NOT CORRECT, and will
result in substandard performance.
CUBE SIZE CONTROL
EVAPORATOR
CAP, SEAL
WITH FOOD
GRADE
SEALANT
PLASTIC TUBE
INSTALL BETWEEN
CUPS
CLIPS