14. Remove the two screws from the reservoir
water trough and remove the trough.
Remove the hex-head screw from the water
pump shield and remove the shield.
16. Remove the water fill tube from the notch in
the water pump bracket, and pull the free end of
the water line up, out of the unit.
17. Pull out on the left
and right water
distributor retainers
and remove the tabs
from the slots in the
evaporator, disconnect
it from the hose, and
remove it.
18. Remove the four screws from the evaporator,
then carefully lift the evaporator just high enough to
remove the two right spacers.
Remove the Permagum from the liner channel.
20. Lift the cabinet top off the unit and stand it on
the floor near the rear of the unit.
July 2007
Page 24
CS0415
Service Manual
Water Trough
Water Pump Shield
Fill Tube