FOR THE ELECTRICIAN: Electrical Connections
See the NAMEPLATE for current requirements to
determine wire size to be used for electrical
hookup. The cuber requires a solid chassis to
chassis earth ground wire. See Wiring Diagram.
Be certain the cuber is connected to its own
electrical circuit and individually fused. Voltage
variation should not exceed ten percent of the
nameplate rating, even under starting conditions.
Low voltages can cause erratic operation and may
be responsible for serious damage to the
icemaker.
Electrical connections are made at the rear of the
icemaker, inside the junction box.
All external wiring should conform to the
national, state and local electrical code
requirements. Usually an electrical permit and
services of a licensed electrician will be
required.
ELECTRICAL JUNCTION BOX
FUSES or HACR
CIRCUIT BREAKERS
CME865W & CME1002W
December, 1994
Page 8