PRE-INSTALLATION INFORMATION
These two models are modular ice cube machines
that are designed to be connected to a remote
condenser.
The remote condenser coil must be of adequate
size and must NOT have been used with a
mineral oil refrigeration system. Specific Scotsman
remote condensers are recommended.
A stacking kit (KSCMS) is required for stacking
these ice machines. It interconnects the sonor bin
ice level controls. A CME865 or CME1002 may
only be stacked onto models CME865, CME1002,
MCM860, MCM1062 or CMS1002.
These models will fit any 30" wide Scotsman bin,
such as the BH550 or HTB555, without a bin top.
Other bins require a bin top.
Note: The sonar transducer, located in the base of
the machine, must NOT be covered by installation
material (such as a non-Scotsman bin top). The
transducer must have clear access to the ice to be
able to sense the ice level. See page 5 for location.
Model Number
Dimensions
W" x D" x H"
Basic Electrical Min Circuit
Ampacity
Max Fuse
Size
Refrigerant Charge*
(R-404A)
CME865RE-32A
30 x 24 x 27 208-230/60/1
16.5
20
336 oz.
CME865RE-6A
30 x 24 x 27 230/50/1
-
-
336 oz.
CME1002RE-32A
30 x 24 x 27 208-230/60/1
20.5
20
336 oz.
CME1002RE-3A
30 x 24 x 27 208-230/60/3
14.3
15
336 oz.
CME1002RE-6A
30 x 24 x 27 230/50/1
-
-
336 oz.
* This number is for recharging purposes only. - Note: Beginning June 1996, 48 ounces of charge were
added to the ERC301, before that total charge was 288 oz.
Use Scotsman Remote Condenser
••
RCE1001 (single circuit) or ERC301 (single circuit).
Use precharged tubing kit
••
RTE25 (25’)
••
RTE40 (40’)
••
RTE75 (75’)
Air Temperature
(cabinet)
Remote Condenser
Air Temperature
Voltage
Water Temperature
Minimum
50
0
F.
-20
0
F.
-5%
40
0
F
.
Maximum
100
0
F.
120
0
F.
+10%
100
0
F
.
CME865R & CME1002R
June 1996
Page 2