Serial Number
Plate Behind
Front Panel
Air In
Air Out
SPECIFICATIONS
Always refer to the nameplate, located on the back
of the cabinet, for the:
••
model number,
••
serial number,
••
basic electrical
requirements,
••
minimum circuit ampacity,
••
maximum fuse size,
••
and refrigerant charge.
A serial number plate with the model number,
serial number and refrigerant charge is located
behind the front panel, near the control box.
The unit comes from the factory with the correct
refrigerant charge. The refrigerant charge
information is for recharging, should that be
necessary.
All utility connections are made at the back of the
ice maker.
Before beginning installation, be sure that all of the
components necessary for complete assembly of
the ice system are available, and are the correct
components with regard to model, voltage, and
finish.
The CME855 or CME1000 will fit Scotsman bin
BH800 without needing a bin top. Other bins will
require a bin top.
Model Number
Dimensions
W" x D" x H"
Basic Electrical Refrigerant
Type
Min.
Circ.
Amps
Max.
Fuse** Size
Refrigerant
Charge*
CME855AE-32A
42 x 24 x 27
208-230/60/1
R-404A
15.9
20
36 ounces
CME855AE-6A
42 x 24 x 27
230/50/1
R-404A
36 ounces
CME1000AE-32A
42 x 24 x 27
208-230/60/1
R-404A
19.9
20
42 ounces
CME1000AE-3A
42 x 24 x 27
208-230/60/3
R-404A
13.8
15
42 ounces
CME1000AE-6A
42 x 24 x 27
230/50/1
R-404A
42 ounces
* The system charge is in the machine. This number is for recharging purposes only. If the nameplate has a
different value, go by the nameplate. ** Or HACR type circuit breakers.
Air Temperature
Water Temperature
Voltage
Minimum
50
0
F.
40
0
F.
-5%
Maximum
100
0
F.
100
0
F.
+10%
CME855A & CME1000A
December, 1994
Page 2