20. The dispense head can now be brixed and the system will be ready to use.
CCOOL 37FF SWITCH PANEL OPERATION
ELECTRICAL SWITCHES
CARBONATOR RESET --- This switch resets the carbonator fill pump(s) if they have timed out or are
over temperature due to a fault condition.
REFRIGERATION ON/OFF------- This switch isolates the refrigeration system
SODA ON/OFF-----------------
This switch isolates the dual soda recirc pumps
CARB PUMP ON/OFF--------- This switch isolates the dual carbonator pumps
HEAT DUMP AND GLYCOL MODULE INSTALLATION - WATER COOLED UNITS
HEAT DUMP - GENERAL GUIDELINES
1. It is important that the heat dump is sited correctly to enable it to work efficiently. The guidelines
below should be adhered to wherever possible.
2. Ensure the unit is sited on an outside wall (preferably non south facing) in the correct orientation
out of direct sunlight.
3. Ensure there are no other heat sources, i.e. a condensing unit or another heat dump, in the
immediate vicinity, where hot air may be re-circulating.
4. Use the recommended tubing (15mm O/D, 10mm I/D Special EVA) to connect the base unit to
the heat dump. Do not use PVC braided tube, as this is not compatible with glycol and will
degrade over a period of time.
3
∅
MAINS ELECTRICAL SUPPLY SWITCH
∅
REFRIGERATION SWITCH
∅
CARBONATOR PUMP SWITCH
∅
SODA RECIRC PUMP SWITCH