C1448, C1848, C2148 E Series
Remote Condenser Models - User Manual
February 2016
Page 13
Final Check List:
1. Is the unit located indoors in a controlled
environment?
2. Is the condenser located where it can receive
adequate cooling air?
3. Has the correct electrical power been supplied to
the machine?
4. Have all the water supply connections been
made?
5. Have all the drain connections been made?
6. Has the remote condenser been properly
installed?
7. Has the interconnecting tubing been properly
routed between the remote condenser and the ice
machine?
8. Have the quick connects been properly
connected?
9. Has the power supply wire from the ice machine
to the remote condenser been properly run and
connected?
10. Has the unit been leveled?
11. Have all unpacking materials been removed?
12. Is the water pressure adequate?
13. Have the drain connections been checked for
leaks?
14. Has the bin interior been wiped clean or sanitized?
15. Have any water filter cartridges been replaced?
16. Have all required kits and adapters been properly
installed?
Lower Light and Switch Panel
This user accessible panel provides important
operational information and duplicates the lights and
switches on the controller. It also allows access to
the On and Off buttons that operate the ice machine.
Sometimes access to the switches should be limited
to prevent unauthorized operation. For that purpose
a fixed panel is shipped in the hardware package.
The fixed panel cannot be opened.
To install the fixed panel:
1. Remove the front panel and remove the bezel.
2. Spread the bezel frame open and remove
original door, insert fixed panel into bezel. Be
sure it is in the closed position.
3. Return bezel to panel and install panel on unit.
Open door to access On
and Off switch buttons.