Page 7
Page 7
MIN.
10
°
C
5
°
C
1 bar
-10%
Important operating requirements:
Air temperature
Water temperature
Water pressure
Electr. voltage variations
from voltage rating
specified
on nameplate
SPECIFICATIONS
ELECTRONIC CUBER MODEL AC 176
MAX.
40
°
C
35
°
C
5 bar
+10%
ice making capacity
NOTE
. With the unit in "built-in" conditions, the ice production is gradually reduced in respect to the
levels shown in the graf, up to a maximum of 10% at room temperatures higher than 32
°
C.
The daily ice-making capacity is directly related to the condenser air inlet temperature, water
temperature conditions of the condenser air filter and age of the machine.
To keep your SCOTSMAN CUBER at peak performance levels, periodic maintenance checks must
be carried out as indicated on Maintenance and Cleaning section of this manual.
AIR COOLED MODELS
WATER TEMPERATURE
AMBIENT
TEMPERA
TURE
ICE PR
ODUCED PER 24 HRS
.
WATER COOLED MODELS
84
82
80
78
76
74
72
70
68
66
64
62
60
58
56
Kg.
10
21
32
38
°
C
o
32
27
21
15
10
°
C
o
WATER TEMPERATURE
AMBIENT
TEMPERA
TURE
ICE PR
ODUCED PER 24 HRS
.
86
84
82
80
78
76
74
72
70
68
66
64
62
60
58
Kg.
10
21
32
38
°
C
o
32
27
21
15
10
°
C
o