Other Antennas
The range and performance of this equipment can be improved by the addition of more efficient
antennas*. These can be installed either inside or outside the building and are connected to the
transmitter with 50 OHM coaxial cable.
Glass mount antenna (UHFGM): for installation on the inside of a suitable window. This can boost
range, especially if it is required in one direction from the building.
The center fed half wave dipole, measuring approximately 12 inches from tip to tip, will provide
excellent all round local signaling. This can be mounted either inside or outside a building. Two
versions are available:
1) a light duty antenna suitable for sheltered environments/internal installation (LUHFDP).
2) a heavy duty stainless unit with optional mounting hardware for more arduous applications
(UHFDP).
Pre-terminated coaxial feeder cables are available for 5, 10 or 15 meter requirements.
Note !
High frequencies can equate to high power losses. Always use quality cable. RG58 is only
acceptable on cable runs of up to 5 meters. We recommend RG213, or equivalent, on greater lengths.
If in doubt consult your dealer.
*subject to license conditions. Specifically, mounting height and Effective Radiated Power (ERP)
.
Service Information
If you experience a problem with your equipment, please contact the distributor from whom it was
purchased. In any event, ensure you have the systems details at hand for reference purposes.
Record your system details here for quick reference:-
Date supplied____/____/____ Serial Number of the base console_________(where applicable)
Transmitter frequency ___ ___ ___.___ ___ ___MHz FCC Approval No: JRNUSASERILINK
Number of pagers supplied with the system ________
Transmitter baud rate ______________
Pager ID port 1 NO __________________ Pager ID port 1 NC__________________
Pager ID port 2 NO __________________ Pager ID port 2 NC__________________
Pager ID port 3 NO __________________ Pager ID port 3 NC__________________
Pager ID port 4 NO __________________ Pager ID port 4 NC__________________
Pager ID port 5 NO __________________ Pager ID port 5 NC__________________
Pager ID port 6 NO __________________ Pager ID port 6 NC__________________
Pager ID port 7 NO __________________ Pager ID port 7 NC__________________
Pager ID port 8 NO __________________ Pager ID port 8 NC__________________
Prefix the Pager ID with (A) for alpha and (N) for numeric pagers
For information on individual pager types, refer to the appropriate pager manual