System Overview

 

 

The Scope DigiLink DL4DCUSA & DL8DCUSA are DC powered (12 to 13.8V dc), programmable radio paging 
systems which can be used to transmit both text and numeric messages direct to pocket pagers carried by 
individuals or entire groups.  The unit is supplied with either 4 or 8 inputs, which can be hardware configured to 
accept either dry contact (no voltage) or voltage (5-18V dc) triggers. Each input is pre-programmed as either 
N/O (Normally Open), N/C (Normally Closed) or C/S (Change of State). Triggering any of the inputs (zones) will 
result in a pre-programmed message (up to 40 characters) being transmitted to the selected pager or group of 
pagers.  
 
The unit can be programmed to repeat transmit (1,2,3 transmissions or until reset) if required. In addition, the 
trigger period can be defined (period for which the zone must remain in the active state before triggering). One 
input can be configured as a Reset to clear any current transmission cycles. This can also be used as an 
“Arm/Disarm” facility for the alarm inputs. Selected inputs can also be set to 24 hour (always armed) mode (for 
use as “Panic” buttons etc.). Various other parameters can be programmed to suit specific user requirements.  
 
The Configuration Data sheets accompanying your system will detail how all the various parameters have been 
set. It is vital that you retain this information in a safe place as you will need to quote the unit’s serial number in 
the unlikely event that you experience any problems. You will also need this information should you wish to 
order more pagers (these must be matched to the identity of your system).  
 
For advanced users who wish to program the unit themselves, a Programming Interface must be purchased. 
This provides a Windows based menu driven application running on a PC serial port, allowing all functions to be 
programmed and stored in the system’s secure non-volatile memory. Full details can be found in the SCPMON 
Monitor Program Help files. 
 
 

Section 1: Installation 

 
The information contained in this Section is intended for use by authorized system installation 
engineers only. Unqualified personnel should not undertake installation of this equipment under any 
circumstances whatsoever. 

 

Location of the hardware 

 

Before locating the hardware in any given location, it is important to take into account the range of operation that 
you require to obtain from your system.  The standard transmitter can quite easily provide ranges of up to a mile 
or more and will provide excellent propagation on most industrial sites, covering a considerable area with just a 
quarter wave antenna (BNC terminated) connected directly to the unit.   
 
For coverage of very large sites, or where exceptionally difficult operating conditions exist, it may be 
advantageous to install an external antenna.  Installing the transmitter on the second or third floor of a building 
will more often than not boost overall range.  However, horizontal range is not always required as much as 
propagation through a multi-story  building.  Here it may be more useful to use a small external antenna 
mounted outside the building at half the building height. Sometimes range is required more in one direction than 
in the other:  moving the aerial to one side of the building can provide a bias in the required direction, which may 
overcome the range difficulties. (See section: 

Other Antennas

).

 

 

Important:

 coaxial feeds which are longer than 5 meters must employ low loss 50 ohm coax.  We normally do 

not recommend feeds of more than 15 meters for standard applications.  However, we suggest you contact our 
technical department where other considerations may prove this to be impractical.   
 
A further consideration that must be taken into account is the length and location of the dry contact cables. To 
avoid interference and possible false triggering, cable runs should be kept to a minimum (ideally less than 10 
meters) and should be isolated from other cabling (e.g. mains, telecoms. PC networks, etc).  

Summary of Contents for Digilink MK2 DL4EDC

Page 1: ...Quantum House Steamer Quay Totnes Devon TQ9 5AL Tel 441803860700Fax 441803863716Email sales scope uk comWeb www scope uk com DIGEDC5 Installation User Manual Digilink MK2 Digilink MK2 Digilink MK2 Digilink MK2 Digilink MK2 Digilink Uhf Digilink Uhf Digilink Uhf Digilink Uhf Digilink Uhf ...

Page 2: ...se You should obtain the FCC Rules and Regulations Title 47 Part 80 to End including Parts 90 and 95 available from the US Gov Printing Office GPO Bookstore FCC Office or www fcc gov oet info rules Important Safety Information Scope products are designed to operate safely when installed and used according to general safety practices The following requirements should be observed at all times Do NOT...

Page 3: ...ired will vary between applications If portable equipment has been dropped or is worn by a person involved in an accident the unit should be tested again before re use It must be stressed that the physical range tests are essential and that any construction work or movement of plant or equipment could alter the signaling capability of the unit Radio equipment like any other requires servicing from...

Page 4: ...irect special incidental or consequential damages resulting from any defect in the product even if advised of the possibility of such damages The warranties and remedies set forth above are exclusive and in lieu of all others oral or written expressed or implied No Scope distributor dealer agent or employee is authorized to make any modification extension or addition to this warranty Some states d...

Page 5: ...tem s secure non volatile memory Full details can be found in the SCPMON Monitor Program Help files Section 1 Installation The information contained in this Section is intended for use by authorized system installation engineers only Unqualified personnel should not undertake installation of this equipment under any circumstances whatsoever Location of the hardware Before locating the hardware in ...

Page 6: ...ce of the system will be affected by the type of material the unit is mounted on and its surroundings The following is a list of materials that this transmitter will be adversely affected by if mounted on or if mounted in close proximity to a Foil back wallboard b Metal mesh or wire reinforced glass c Metal sheeting large mirrors or suspended ceilings d Lift shafts All of the above can reflect rad...

Page 7: ...ter unit itself ensure that the previous criteria covered under the section headed Location of the Hardware have been strictly adhered to also see section headed Other Antennas 6 Connect the input cables to the zone terminals Unless the unit has been specifically configured for voltage input these should be simple dry no voltage contacts only i e isolated switch or relay contacts If configured for...

Page 8: ...Version DIGUSDCECO Issue 1 7 Installation The Transcoder PCB contains static sensitive components Care should be taken to avoid contact wherever possible and anti static precautions should be observed during installation ...

Page 9: ... be noted that use of a siren will severely shorten the battery life Problems and Fault Finding 1 Check that the input cables are connected to the active zones For a 4 zone unit these are the lowermost terminal blocks on the main PCB see diagram page 9 2 Check the Configuration Data sheet supplied with the system to confirm the active trigger state of each input i e Normally Open Normally Closed o...

Page 10: ...DigiLink US DC Version DIGUSDC 02 00 Issue 3 9 Transcoder PCB terminal connections ...

Page 11: ...lt your dealer subject to license conditions Specifically mounting height and Effective Radiated Power ERP Service Information If you experience a problem with your equipment please contact the distributor from whom it was purchased In any event ensure you have the systems details at hand for reference purposes Record your system details here for quick reference Date supplied____ ____ ____ Serial ...

Page 12: ...e 450 470 MHz Channel Spacing 25 KHz or 12 5KHz TX Baud Rate 512 or 1200 FCC Approval No JRNUSAECOLINK General Ports 4 or 8 dry contact voltage inputs configurable Open Collector siren output 1A max COM1 serial port for programming function only Footprint mm 184 L x 138 W x 45 D max excluding aerial Scope s policy is one of continuous development and specifications are subject to change without pr...