8 of 22
Chapter 3 – Operator Maintenance Procedure Details
Checking the Foil Rewind and Unwind Shaft Tension
Once a week, check the Foil rewind and unwind shafts for the correct expanding operation (tension),
as follows:
1.
Open the Foil System's cover.
2.
On the operator station, in
REMOTE CONTROL
mode, press
TENSION
.
3.
Record the current tension values to use as a reference. You may need to obtain these values
again after the test.
4.
Test the tension:
Set the tension to
0
. Verify that you can easily rotate the differential shaft ring.
Set the tension to
100
. Verify that you cannot manually rotate the differential shaft ring.
If the differential shaft ring did not react as specified in step
4, call your service representative.