background image

2 OF 6 

  WARNING: Read carefully and understand all 

INSTRUCTIONS before operating. Failure to follow the safety 
rules and other basic safety precautions may result in serious 
personal injury. 

 

 

A. MACHINE DESCRIPTION 

PUMP:

 Self-priming, volumetric, diaphragm pump, equipped with by-pass valve. 

MOTOR:

 Asynchronous motor, single-phase, 2 pole, closed type (protection class IP55 in conformance with 

EN 60034-5-86 regulations) self-ventilated. 

B. TECHNICAL DATA 

B1. Configuration 

Item No. 

Pump model 

Voltage 

Suction Hose 

Delivery Hose 

Nozzle 

Flow Meter 

SPS240VADEF 

SAP240V25L 

240V 

1.5M 

6M 

Manual 

Yes 

SPS240VADEFA  SAP240V25L 

240V 

1.5M 

6M 

Auto 

Yes 

C. OPERATING CONDITIONS 

C1. ENVIRONMENTAL CONDITIONS 

TEMPERATURE

: Min. -10oC

1

4℉)

  / Max. +60oC(14

0℉)

 

RELATIVE HUMIDITY

: Max. 90% 

  ATTENTION! 

The temperature limits shown should be adhered to, to prevent damage to the pump. 

 

C2. ELECTRICAL POWER SUPPLY 

Depending  on  the  model,  the  pump  must  be  supplied  by  a  single-phase  alternating  current  line  whose 

nominal values are shown in the table in Paragraph B1 – ELECTRICAL SPECIFICATIONS. 

The maximum acceptable variations from the electrical parameters are:   

Voltage:

 +/-5% of the nominal value 

Frequency:

 +/-2% of the nominal value 

  ATTENTION! 

Power from lines with values outside the indicated limits can damage the electrical components. 

 

C3. WORKING CYCLE 

The pumps are designed for continuous use under maximum back pressure. 

  ATTENTION! 

Functioning  under  by-pass  conditions  is  only  allowed  for  brief  periods  of  time  (2-3  minutes 

maximum). 

 