3 OF 4
C. TECHNICAL DATA
C1. Electrical Data
Kit Model
PUMP MODEL
FUSES
ELECTRICAL POWER
FLOW RATE
Current
Voltage(V)
GPM/LPM
SPKP12V40
SPT12V40LPM
25
DC
12
10/40
SPKP24V40
SPT24V40LPM
15
DC
24
10/40
D. OPERATING CONDITIONS
Refer to pump manuals for SPT12V40LPM & SPT24V40LPM
E. Installation and Operation
The pump box includes 1pc DC pump, connecters, suction hose with filter, delivery hose and manual
nozzle.
1 ) Before using, put the pump box on level footing. Then take out the nozzle and delivery hose, rotating
the hose connectors to the best operation position.
2 ) Take out the suction hose and rotating the hose connectors to best operation position put the suction
hose with filter to the drum bottom.
3 ) Check all hoses and fittings.
4 ) After using, take out the suction hose and stand for several minutes to drain fuel in the hose.
5 ) At the same time, start the pump and run dry for several seconds to drain remaining fuel.
6 ) After emptying the fuel in the hose and pump, please retract the suction hose to the box then retract
the nozzle and delivery hose for better storing and moving.
NOTE : Please refer to the Pump Manuals for applications and more details.