1.Safety Instructions

Warning!

• Read the operating instructions completely

before use and follow the safety instructions.

• Ensure that only trained staff work with the

instrument.
Protective ground contact

• Make sure the socket must be earthed

(protective ground contact) before use. 

• Wear the personal protective equipment in accordance

with the hazard category of the media to be processed.

 -  Splashing of liquids.

 -  vibration force led to broken glass container.

 -  The body

hair

clothes

jewelry are inhaled.

• Use the instrument following the safety instructions and

profession safety rules to avoid any accident.

• Users are not allowed to touch moving parts of the

instrument to avoid any accidents. Pay attention to protect 

hands or fingers from rolling when moving the instrument.

• Set up the instrument in a spacious area on an stable,

clean, non-slip, dry and fireproof surface. Do not operate 

the instrument in explosive atmospheres, with hazardous 

substances or under water.

• Observe the vessel on the shaking table for medium

splashing out of liquid when setting the motor speed. Reduce 

the motor speed if the instrument is not running smoothly.

• Accessories must be securely attached to the instrument

so that it cannot come off by itselves, and vessels must be 

firmly placed on the shaking table to avoid any injury.

• Working with combustible media or flammable materials

may result in additional hazards. Only process media that 

will not react dangerously to the extra energy produced 

through processing should be used on the instrument. 

• Safe operation is only guaranteed with the accessories

described in the 

Accessories

 chapter and by following 

the operating instructions in full. Always disconnect the 

plug before fitting accessories. Check the instrument and 

accessories beforehand for damage each time you use them. 

Do not use damaged components.

• The instrument may only be opened by trained technicians.

And always disconnect the plug beforehand.

• The operating voltage required as stated on the instrument

and voltage in the supply network must match. 

• Do not cover the instrument. Protect the instrument and

accessories from bumps and impacts.

• Keep away from high magnetic field.

Summary of Contents for SK-L180-Pro

Page 1: ...igital shaker 7 5Kg Linear Digital shaker 2 5Kg Orbital Digital shaker 2 5Kg SK L330 Pro SK O330 Pro SK L180 Pro SK O180 Pro Please read the User Manual and the related Video of this instrument on our...

Page 2: ...4 Trial Run 3 5 Control and Set 4 5 1 Control 4 5 2 Set 5 5 2 1 Set Time 5 5 2 2 Setting Speed 5 6 Operating Modes 6 6 1 Mode A 6 6 2 Mode B 7 6 3 Switching the Mode 7 6 4 Switch the shaking directio...

Page 3: ...rmation Serial Number on the rear panel Description of problem i e hardware or software Methods and procedures adopted to resolve the problems Your contact information Warranty You have purchased a Sc...

Page 4: ...s substances or under water Observe the vessel on the shaking table for medium splashing out of liquid when setting the motor speed Reduce the motor speed if the instrument is not running smoothly Acc...

Page 5: ...r for technical support Note If there is any apparent damage to the system please do not plug it into the power line 3 2 Listing of Items The packing includes the following items Items Qty Main unit 1...

Page 6: ...wnward with the wrench until the instrument is standing securely on the surface Figure 1 5 Control and Set 5 1 Control Shaking table Time knob LCD time LCD speed Figure 2 Items Descriptions Speed knob...

Page 7: ...ion If continuous mode is selected the shake can continue its shaking function for any amount of time with the previously set speed If timed mode is selected the shaker can run in the set time After t...

Page 8: ...the upper speed limit rpm which can be set by pressing the speed knob and turning at the same time Figure 3 The LCD displays run modes StA A or B for about 2 seconds Figure 4 The set or stored speed v...

Page 9: ...splays the upper speed limit rpm which cannot be changed Figure 7 The LCD displays run modes StA for about 2 seconds Figure 8 The set speed value is shown in the left display and the set time value is...

Page 10: ...curely in the middle of the shaking table no matter one or multiple shaking vessels are placed 8 Faults When switched ON the instrument doesn t work Check whether the power cable fitted well Check whe...

Page 11: ...ase request information from manufacturer or your supplier Before using another than the recommended method for cleaning or decontamination the user must ascertain that this method does not destroy th...

Page 12: ...brushless motor Motor rating input W 28 Motor rating output W 15 Permissible ON time 100 Speed range rpm 100 350 SK L330 Pro 100 500 SK O330 Pro 100 350 SK L180 Pro 100 800 SK O180 Pro Speed display L...

Page 13: ...0V 50Hz 60Hz 832010039999 SK O180 Pro Orbital Digital Shaker 2 5Kg No Attachment Euro plug 110V 220V 50Hz 60Hz Cat No Descriptions 832010049999 SK O180 Pro Orbital Digital Shaker 2 5Kg No Attachment U...

Page 14: ...ker 7 5 Kg No Attachment USA plug 110V 220V 50Hz 60Hz Accessories Accessories Figure Cat No and Designation Operation mode 18900027 SK330 1 SK 330 1 Universal Attachment 18900040 SK330 3 SK330 3 Lengt...

Page 15: ...lask Volume 50 ml 18900031 SK330 2 3 Fixing Clips for Flask Volume 100 ml 18900032 SK330 2 4 Fixing Clips for F l a s k Vo l u m e 200 250 ml 18900033 SK330 2 5 Fixing Clips for Flask Volume 500 ml 18...

Reviews: