background image

Tube Roller

 

LCD display 

LCD  displays  the  real  working  state 

and all setting values. 

Power 

switch 

I/O

 

Switch ON or OFF the instrument. 

Table 2 

Figure 3 

Items 

Default settings 

Speed 

control 

knob 

Rotating 

speed 

control 

knob 

to 

start/stop rotating function. 

Power 

light  Green LED display light. 

Power

 

LED  light  shows  green  when  switch 

on. 

Power 

switch 

I/O

 

Switch ON or OFF the instrument. 

Table 3 

4.2 Display 

Figure 3 

Display 

Descriptions 

Set 

Display when set target value. 

Err

 

Display in case of error happening. 

Display area 

When 

Set

  display,  this  area  shows 

setting value; When 

Set

 disappears, this 

area shows running value. 

Table 4 

Summary of Contents for SCI-T6-Pro

Page 1: ...T6 Pro SCI T6 S LCD Digital Tube Roller Analog Tube Roller Please read the User Manual carefully before use and follow all operating and safety instructions Technical specifications and outline are subject to change without prior notice www scilogex com ...

Page 2: ...roper Use 3 3 Inspection 3 3 1 Receiving Inspection 3 3 2 Listing of Items 3 4 Control and Display 4 4 1 Control 4 4 2 Display 5 5 Operation 6 6 Faults 6 7 Maintenance and Cleaning 7 8 Associated standards and regulations 7 9 Specifications 8 10 Ordering Informations 8 ...

Page 3: ...umber on the rear panel Certification Description of problem i e hardware or software Methods and procedures adopted to resolve the problems Your contact information Warranty This instrument is warranted to be free from defects in materials and workmanship under normal use and service for a period of 24 months from the date of invoice The warranty is extended only to the original purchaser It shal...

Page 4: ...tmospheres with hazardous substances or under water If the instrument does not run smoothly please decrease the motor speed Firmly secure the accessories and vessels in place to avoid damage or risk Preparation of samples may lead to dangerous flammable Only process samples that will not react dangerous Use the standard accessories listed in the accessories section and follow the instructions to u...

Page 5: ...r 1 Do not use the accessories recommended by the manufacturer or failure to use the instructions may be caused unsafe situation 3 Inspection 3 1 Receiving Inspection Unpack the instrument carefully and check for any damages which may have arisen during transport If it happens please contact manufacturer supplier for technical support Note If there is any apparent damage to the system please do no...

Page 6: ...olors of LED light show the value for speed or time that LCD screen currently displays Green LED light shows that LCD screen currently displays speed Red LED light shows that LCD screen currently displays time Power Overload protection light Power Overload Green Red LED display light LED light shows green when switch on LED light shows red when starts overload protection When the torque reaches li...

Page 7: ...ntrol knob to start stop rotating function Power light Green LED display light Power LED light shows green when switch on Power switch I O Switch ON or OFF the instrument Table 3 4 2 Display Figure 3 Display Descriptions Set Display when set target value Err Display in case of error happening Display area When Set display this area shows setting value When Set disappears this area shows running va...

Page 8: ...opped at any time by pressing the speed timer control knob If the knob is pressed again motion will start again and the timer will restart countdown When the timer reaches zero the unit will be automatically halted and an alert will sound If these operations above are normal the instrument is ready to operate If not the instrument may be damaged during transportation please contact technical suppo...

Page 9: ...e user must ascertain with the manufacturer that this method will not damage the instrument Wear the proper protective gloves during cleaning of the instrument Note Electronic device cannot clean with cleanser If you require maintenance service must be cleaned the instrument in advance to avoid pollution of hazardous substances and to send back into original packing If the instrument will not use ...

Page 10: ...requency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense 9 Specifications Items Specifications LCD digital model Classic model Voltage VA...

Page 11: ...rs 100V 240V 50HZ 60HZ Cn plug 823222219999 SCI T6 Pro LCD Digital Tube Roller variable speed 6 rollers 100V 240V 50HZ 60HZ Euro plug 823222319999 SCI T6 Pro LCD Digital Tube Roller variable speed 6 rollers 100V 240V 50HZ 60HZ UK plug 823220019999 SCI T6 S Classic Tube Roller variable speed 6 rollers 100V 240V 50HZ 60HZ US plug 823220119999 SCI T6 S Classic Tube Roller variable speed 6 rollers 100...

Page 12: ...SCILOGEX LLC 1275 Cromwell Ave Suite C6 Rocky Hill CT 06067 USA Tel 1 860 436 9221 Fax 1 860 436 9745 info scilogex com www scilogex com ...