background image

 

ROTATE/ROCK 
 
Enviro-Genie

  comes  equipped  with  a  magnetic 

platform  that  is  used  for  rotating  and  rocking.  
Installing/removing  the  magnetic  platform  is  easy, 
but  may  take  a  few  times  to  get  used  to.    Try  the 
following technique: 
 
Install the magnetic platform by first unscrewing the 
lock shaft until the end of the lock shaft is flush with 
the right hand sidewall of the inside of the chamber.   
 
 
 
 
 
 
 
 
 
 
 
 
 
Grab  the  magnetic  platform  with  the  label  side  up, 
so that you can read the label.  Hold the platform in 
the  chamber  and  insert  the  hex  shaft  on  the  left 
side  of  the  chamber  into  the  hex  hole  in  the 
magnetic  platform.    You  may  need  to  rotate  the 
platform slightly to align the shaft with the hole. 
 
 
 
 
 
 
 
 
 
 
 
 
Now  hold  up  the  right  side  of  the  platform,  while 
depressing  the  blue  lock  release.    Screw  the  lock 
shaft into the hole in the magnetic platform making 
sure the blue lock release is depressed.  When the 
lock  shaft  is  screwed  all  the  way  in,  let  go  of  the 
lock release.   
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 

To  remove  the  platform,  reverse  the  above 
procedure. 

 
To select rotating mode: 

1.  Press the lock release. 
2.  Shift the magnetic platform to the right. 
3.  While shifting the platform right, release the 

lock  release  and  line  up  the  hex  shaft  to 
engage the lock shaft properly. 

4.  The  platform  will  lock  in  place  when  it 

reaches the correct position. 

 

 
 
 
 

 
 
 
 
 
 
 
 

To select rocking mode: 

1.   Press the lock release. 
2.  Shift the magnetic platform to the left. 
3.  While  shifting  the  platform  left,  release  the 

lock  release  and  rotate  the  platform  to  line 
up the pin and the pin slot in the end of   the 
platform.  Shift the platform onto the pin. 

4.  The  platform  will  lock  in  place  when  it 

reaches the correct position.  

 

 
 
 
 
 
 
 

Summary of Contents for ENVIRO-GENIE Series

Page 1: ...S A Phone 631 567 4700 Fax 631 567 5896 Toll Free 888 850 6208 Customer Service custsvc scientificindustries com www scientificindustries com ENVIRO GENIE OPERATING INSTRUCTIONS Models SI 1200 throug...

Page 2: ...d stirring speed temperature and time all of which are shown on a large easy to read display for accurate reproducible conditions Visible and audible alarms for both temperature and time FEATURES 4 C...

Page 3: ...on is used for starting stopping the mixer TEMP ON OFF button is used for starting stopping the temperature regulator START STOP button is used for starting stopping the timer DISPLAY CONTENTS Power o...

Page 4: ...TION Temperature regulation can be turned ON OFF by pressing the TEMP ON OFF button or the START STOP button While the temperature regulation is working the TEMP ON OFF LED will be GREEN After the des...

Page 5: ...ing the UP and DOWN buttons to make them equal Wait 20 minutes Repeat this procedure until the temperature sensor reading equals the lab thermometer reading Press the button The display will move to t...

Page 6: ...the platform while depressing the blue lock release Screw the lock shaft into the hole in the magnetic platform making sure the blue lock release is depressed When the lock shaft is screwed all the w...

Page 7: ...e different motions within the tubes First select the size clip plate required The large clips hold 28 30mm dia 50ml tubes the medium clips hold 15 17mm dia 15ml tubes and the small clips hold 10 13mm...

Page 8: ...erminating character CONTROL COMMANDS TIME Mixing and temperature control time Enter commanded time as follows To enter 7 Hrs 23 Min type Time 723 followed by the enter key TON Turn on data output Dat...

Page 9: ...estore all factory preset values WINDOWS QUICK START Connect cable to Enviro Genie and PC Start Windows Hyperterminal Start Programs Accessories Communication Hyperterminal Double Click on Hypertermin...

Page 10: ...steel trays 24 bag mounting strips 9 SI 1130 2 Clip Plates for Hybridization Tubes 10 SI 1131 1 Stackable Shelf SI 1132 Serial Cable picture not shown 11 SI 1134 2 Universal Clip Plates 12 SI 1135 1 M...

Page 11: ...0 916 KIT RS232 CABLE ENVIRO GENIE 2A 318 0510 02 LINECORD 120V 2B 0A 1101 015 LINECORD 230V W O PLUG 2C 0A 1102 015 LINECORD 230V EUROPEAN PLUG 2D 0A 1103 015 LINECORD 230V BRITISH PLUG 2E 0A 1104 01...

Page 12: ...y and voltage Indicator Part Description 1 0K 1200 911 KIT MOTOR ASSEMBLY ENVIRO GENIE 2 0K 1200 922 KIT POWER DISTRIBUTION BOARD FOR LCD DISPLAY 3 0K 1200 913 KIT LINE FILTER ENVIRO GENIE 4 0K 1200 9...

Page 13: ...0K 1200 908 KIT MOTOR DRIVE ENVIRO GENIE 2 0K 1200 909 KIT SMALL GEAR 30T ENVIRO GENIE 3 0K 1200 910 KIT HEX SHAFT ENVIRO GENIE Indicator Part Description 1 0K 1200 904 KIT TEC ENVIRO GENIE 2 0K 1200...

Page 14: ...ion 1 0M 1200 207 BACK PANEL ENVIRO GENIE 2 0K 1200 903 KIT FAN BACK PANEL ENVIRO GENIE 3 HWP0034 BUMPER 1 DIA X 1 LG Indicator Part Description 1 0K 1200 923 KIT LCD DISPLAY BOARD 2 0K 1200 924 KIT L...

Page 15: ...efore cleaning Do not immerse CAUTION Do not use Enviro Genie in hazardous atmospheres or with hazardous materials CAUTION Do not use Enviro Genie in applications such as mixing of flammable materials...

Page 16: ...16 U S A 631 567 4700 Fax 631 567 5896 Toll Free 888 850 6208 Email for Customer Service custsvc scientificindustries com Email for all other information or inquiries info scientificindustries com www...