background image

2

EASy Reference Guide - S38SX

Service Bulletin

the outrigger into proper setup position. The warning 

message will go away and you can resume pumping 

concrete.

Bypass Outrigger Sensors

If you don't want to reposition the outrigger, press the 

CLEAR button as instructed on the screen. The warning 

message will go away and the outrigger sensors will be 

bypassed - meaning the machine will no longer monitor 

the position of the outriggers. The placing boom will still 

be limited to the selected working range.

If you bypass the outrigger sensors, you are responsi-

ble for maintaining the setup of your machine, ensure 

the outriggers are not moved until the after boom is fold-

ed up and placed in the cradle.

If you try and move the boom with the "

Check outrig-

gers !

" warning message displayed, you will receive an-

other fault message "

! Machine Safety Stop! Machine 

not correctly stabilized!

" A horn will sound and the 

boom will stop moving. To continue moving the boom 

press the QUIT button once. The warning horn will shut-

off, but the message will still appear. Press the QUIT 

button again to clear the fault message. The boom can 

now be operated normally.

! Machine Safety Stop !

Machine not correctly

stabilized !

18.09.18(ddmmyy)13:09:37

(E45H)

[QUIT] ???

->[QUIT]

!!! ERROR !!!

STOP! 

2

Temporary Truck Shutdown.

At times you may want to setup the machine and then 

shut the truck off while you wait for concrete.

With the machine properly setup, shut the truck engine 

off. When you are ready to resume, turn the truck engine 

back on. The Vector control panel will power up. You will 

receive the following warning "

! Machine Safety Stop! 

Boom is Not in Cradle!

" Press the QUIT button once 

to silence the horn, press the QUIT button again to clear 

the fault message. 

! Machine Safety Stop !

Boom Is Not In Cradle !

18.09.18(ddmmyy)13:34:37

(S21H)

[QUIT] ???

->[QUIT]

!!! ERROR !!!

OK

The next message to appear is "

Is the unit supported 

by all outriggers?

" Since we have already properly set 

up the machine, all we have to do is the press the out-

rigger buttons on both sides of the unit for 5 seconds 

- or until you hear the horn beep. The machine is now 

ready to operate.

Is the unit

supported

by all

outriggers?

EASy assistant

OK

Is the unit

supported

by all

outriggers?

EASy assistant

OK

Summary of Contents for EASy S38SX

Page 1: ...lt If you receive a serious fault that effects the safe opera tion of the machine the placing boom will stop remote box will be disabled and the horn will sound The mes sage Safety Shutdown is display...

Page 2: ...hut off but the message will still appear Press the QUIT button again to clear the fault message The boom can now be operated normally Machine Safety Stop Machine not correctly stabilized 18 09 18 ddm...

Page 3: ...ecure the front outrigger with the outrigger lock OFF Figure 3 Fully extend outriggers on the working side Extend the front outrigger on the non working side until you hear the horn beep twice Lower t...

Page 4: ...40 41 40 2 150 40 150 40 0 Joint D dependence on joint E The boom sensor system will not allow joint D to be moved until joint E has been opened 41 If you attempt to move joint D before joint E is op...

Page 5: ...teps 1 Raise boom section 1 Figure 9 Raise boom section 1 Figure 10 Slew boom into the working area Figure 11 Fold out boom section 2 Figure 12 Fold out boom section 3 Figure 13 Fold out boom section...

Page 6: ...gger shown on a decal on the outrigger leg by the number of square inches of soil contact Soil pressure PSI total outrigger force lbs area of soil contact sq in total outrigger force lbs Soil pressure...

Page 7: ...ches required to support the outrigger Con sult the table below and select a cribbing size slightly larger than required In this example we recommend a Cribbing size of 40 X 40 1600 sq in Square inch...

Page 8: ...8 EASy Reference Guide S38SX Service Bulletin...

Reviews: