Load Profile
The SEL-787 features a programmable Load Data Pro-
file (LDP) recorder that records as many as 17 metering
quantities into nonvolatile memory at fixed time inter-
vals. The LDP saves several days to several weeks of the
most recent data depending on the LDP settings
(9800 entries total).
Synchronized Phasor Measurement
Combine the SEL-787 with an SEL IRIG-B time source
to measure the system angle in real time with a timing
accuracy of ±10 µs. Measure instantaneous voltage and
current phase angles in real time to improve system oper-
ation with synchrophasor information. Replace state
measurement, study validation, or track system stability.
Use SEL-5077
SYNCHRO
WAV
E
®
Server Software or
SEL-5078-2
SYNCHRO
WAV
E
®
Central Visualization and
Analysis Software to view system angles at multiple
locations for precise system analysis and system-state
measurement (see
Table 5
SEL-787 Metered Values (Model Dependent)
Types of Metering
Instantaneous
RMS Remote
Analogs
Energy
Math Variables
Synchrophasors
Max/Min
Thermal
Demand and Peak Demand
Analog Inputs
Quantity
Description
Currents I
x
W
n
(
x
= A, B, C,
n
= 1, 2, 3, 4)
Winding phase current magnitude and angle, primary A
IN
Neutral current magnitude and angle, primary A
IGW
n
(
n
= 1, 2, 3, 4)
Residual-ground fault current and angle per winding, primary A
3I2W
n
(
n
= 1, 2, 3, 4)
Negative-sequence current and angle per winding, primary A
IOP
z
(
z
= 1, 2, 3)
Differential operate current, scaled to TAP
IRT
z
(
z
= 1, 2, 3)
Differential restraint current, scaled to TAP
I
n
F2, I
n
F4, I
n
F5 (
n
= 1, 2, 3, 4)
Current harmonics, I
n
F2/IOP
n
(%) for 2nd, 4th, 5th harmonics
Voltages VA, VB, VC
Phase voltages and angles, primary volts, for wye-connected potential transformers
Voltages VAB, VBC, VCA
Phase-to-phase voltages and angles, primary volts, for delta-connected potential transformers
Voltage VG
Residual-ground voltage and phase angle, primary volts, for wye-connected potential transformers
Voltage 3V2
Negative-sequence voltage and phase angle, primary volts
Power kVA, kW, kVAR
Calculated apparent, real, and reactive power scaled to primary values (single and three-phase)
a
a
Single-phase power and power factor quantities are not available when delta-connected PTs are used.
Energy MWh, MVARh
Three-phase positive and negative megawatt-hours, megavar-hours
Power Factor PF
Single and three-phase power factor (leading or lagging)
Voltage VS
Synchronism-check voltage channel, voltage magnitude and angle, primary volts
Voltage VDC
Station battery voltage
Frequency FREQ
Measured system frequency (Hz)
Frequency FREQS
Measured frequency (Hz) of synchronism-check channel
V/Hz
Calculated volts/hertz in percent, using highest measured voltage and frequency
AI
x
01–AI
x
04 (
x
= 3, 4, or 5)
Analog inputs
MV01–MV32
Math variables
RA001–RA128
Remote analogs
RTD1–RTD12
RTD temperature measurement (degrees C)