![Schweitzer Engineering Laboratories SEL-421-4 Instruction Manual Download Page 1420](http://html.mh-extra.com/html/schweitzer-engineering-laboratories/sel-421-4/sel-421-4_instruction-manual_12167261420.webp)
18.14
SEL-400 Series Relays
Instruction Manual
Date Code 20171006
Synchrophasors
Settings for Synchrophasors
Ethernet Port Settings
The settings found in
are used for configuring synchrophasor data
transmission over an Ethernet port.
Descriptions for some of the settings in
are as follows.
EPMIP
Setting this to Y enables synchrophasor data transmission over Ethernet port. Set-
ting this to N disables the synchrophasor data transmission over Ethernet port.
The EPMIP := Y settings choice can be made when Global setting EPMU := N.
This setting combination will result in the relay ignoring any incoming synchro-
phasor requests regardless of whether the Ethernet port settings are correct or not.
PMOTS[2]
Selects the PMU Output transport scheme for session 1 and 2, respectively.
➤
PMOTS[2] := TCP establishes a single, persistent TCP socket for
transmitting and receiving synchrophasor messages (both commands
and data), as illustrated in
Table 18.4
Ethernet Port 5 Settings for Synchrophasors
Setting
Description
Default
EPMIP
Enable PMU Processing (Y, N)
N
PMOTS1
PMU Output 1 Transport Scheme (OFF, TCP, UDP_S,
UDP_T, UDP_U)
OFF
PMODC1
PMU Output 1 Data Configuration (1–5)
1
PMOIPA1
PMU Output 1 Client IP (Remote) Address (www.xxx.yyy.zzz)
192.168.1.3
PMOTCP1
PMU Output 1TCP/IP (Local) Port Number (1–65534)
4712
PMOUDP1
PMU Output 1 UDP/IP Data (Remote) Port Number (1–65534)
4713
PMOTS2
PMU Output 2 Transport Scheme (OFF, TCP, UDP_S,
UDP_T, UDP_U)
OFF
PMODC2
PMU Output 2 Data Configuration (1–5)
1
PMOIPA2
PMU Output 2 Client IP (Remote) Address (www.xxx.yyy.zzz)
192.168.1.4
PMOTCP2
PMU Output 2 TCP/IP (Local) Port Number (1–65534)
4722
PMOUDP2
PMU Output 2 UDP/IP Data (Remote) Port Number (1–65534)
4714
Figure 18.3
TCP Connection
C37.118
- Synchrophasor Command Start Request
- Synchrophasor Command Stop Request
- Synchrophasor Command Configuration Request 1
- Synchrophasor Command Configuration Request 2
- Synchrophasor Command Header Frame Request
- Synchrophasor Command Extended Frame
C37.118
- Synchrophasor Measurement
- Synchrophasor Configuration Response 1
- Synchrophasor Configuration Response 2
- Synchrophasor Header Frame
TCP Socket
(Persistent)
SEL-400
Summary of Contents for SEL-421-4
Page 6: ...This page intentionally left blank ...
Page 14: ...This page intentionally left blank ...
Page 30: ...This page intentionally left blank ...
Page 104: ...This page intentionally left blank ...
Page 128: ...This page intentionally left blank ...
Page 536: ...This page intentionally left blank ...
Page 584: ...This page intentionally left blank ...
Page 616: ...This page intentionally left blank ...
Page 696: ...This page intentionally left blank ...
Page 750: ...This page intentionally left blank ...
Page 755: ...Instruction Manual PM400 01 NB SEL 400 Series Relays Instruction Manual 20171006 ...
Page 776: ...This page intentionally left blank ...
Page 932: ...This page intentionally left blank ...
Page 976: ...This page intentionally left blank ...
Page 1024: ...This page intentionally left blank ...
Page 1038: ...This page intentionally left blank ...
Page 1064: ...This page intentionally left blank ...
Page 1128: ...This page intentionally left blank ...
Page 1206: ...This page intentionally left blank ...
Page 1316: ...This page intentionally left blank ...
Page 1350: ...This page intentionally left blank ...
Page 1464: ...This page intentionally left blank ...
Page 1468: ...This page intentionally left blank ...
Page 1492: ...This page intentionally left blank ...
Page 1518: ...This page intentionally left blank ...