Schweigen IS4160S Installation Manual Download Page 5

Page 5

2. 

Important Safety Information

Before Installation

1. 

We recommend this appliance be installed or repaired by a qualified Schweigen Home Appliances 
technician. 

2. 

Please see our website 

www.schweigen.com.au

 for recommended installers.

3. 

It is dangerous to modify any part of this appliance. Modification of any kind, will immediately void the 
warranty.

4. 

The manufacturer declines all responsibility in case of failure to adopt proper safety measures.

5. 

Ensure that the location in which this appliance is installed, has good and permanent ventilation.

6. 

Please consult local laws and regulations and install in accordance.

7. 

Use an electrical connector with earth that is correct for your location.

8. 

Check that the voltage in your area corresponds to the appliance as indicated on the rating label.

9. 

This appliance must be connected to an electricity supply with a 

ground connection

.

10. 

Check that the installation and electrical connections are made by a qualified technician and that the 
indicated instructions and local regulations in force are met, using materials that are compliant with 
the applicable legislation.

11. 

The company will not be responsible for installations executed by non-qualified staff and 
installations that fail to heed the applicable legislation on electrical safety (with regard to both 
modes and materials).

12. 

The electrical technical data can be found inside the rangehood, after removing the grease filters.

13. 

The flexible power cable supplied is already connected internally and emerges from the rangehood 
near the air outlet tube.

14. Before installing the electrical connections, you should:

 

Verify that the indicated electrical data coincide with the voltage values and frequency  
of the electrical circuit in the house where the rangehood is to be installed;

 

Check that the premises has electrical protection against short circuits and electrocution,  
pursuant to the applicable legislation;

 

Always switch off the current using the double-pole switch before maintenance and turn  
the power on again for normal use only when the operation has been completed.

Summary of Contents for IS4160S

Page 1: ...www schweigen com au RANGEHOOD INSTALLATION GUIDE IS4160S Revision V4 01 10 21...

Page 2: ...9 Cleaning the Interior 10 Cleaning the Exterior 10 Replacing the Lights 11 6 Installation 12 Rangehood Size vs Cooktop Size 12 Mounting Instructions 13 Recommended Installation Height for Induction...

Page 3: ...your warranty card one is available to download from our website www schweigen com au This appliance and its packaging are produced by processes that minimise waste and respect the environment Please...

Page 4: ...person s including children with reduced physical sensory or mental capabilities or lack of experience and or knowledge Unless the person has been given supervision or instruction concerning the use o...

Page 5: ...are made by a qualified technician and that the indicated instructions and local regulations in force are met using materials that are compliant with the applicable legislation 11 The company will no...

Page 6: ...ling cavity When a rangehood is ducted only into the ceiling space the collection of humidity and grease can present very real health issues and fire hazards Recirculating or non ducted or filtered ra...

Page 7: ...le Outlet 200mm 7 Reducer For Isodrive 650 with single outlet only 8 Corner pieces 9 Filter 10 Light NOTE Filter and light quantity may vary from model to model Important Electronics MUST be accessibl...

Page 8: ...ght cooking High speed for heavy frying or heavy cooking Cleaning periods of metal filters C Signal Filter should be cleaned when C signal appears on the display on average this is every 4 to 5 weeks...

Page 9: ...y important for the liquid soap to not contain granules that could scratch the surface First apply the solution to a soft cloth and then rub the cloth over the rangehood It is important to follow the...

Page 10: ...r Dishwasher Put the filter in the dishwasher and select a short program at low temperature NOTE The colour of the metal mesh filters may change after several washes This is normal and it is not neces...

Page 11: ...he pins of the light bulb with the larger holes inside the light holder Once the pins are in place turn clockwise to secure the light bulb Step 1 Remove the filters from the rangehood Danger Always sw...

Page 12: ...ze In addition to the size the height of the rangehood above the cooktop is important to obtain the best performance INADEQUATE Rangehood smaller than cooking zone ADEQUATE Rangehood same size as cook...

Page 13: ...hweigen recommends a height between 700 750mm Refer to page 19 for further information IMPORTANT If the user decides to install the rangehood at a distance of less than minimum height above the cookin...

Page 14: ...g Please ensure that the round space O is facing front NOTE Mounting plate should be secured to the timber frame in the ceiling Step 2 Attach aluminium flexi duct to the outlet on the rangehood and sc...

Page 15: ...r pieces to the mounting plate and feed aluminium flexi duct into the roof with the motor and main power cable Pull the internal flue up and attach it to the roof mounting plate Step 5 Connect the ran...

Page 16: ...T Please ensure all plastic protection on the rangehood and filters is removed before use Step 6 Install filters once the rangehood has been properly fastened Step 7 Connect the female plug to the mot...

Page 17: ...le models The supplied ducting has been manufactured with an allowance for the back draft fins to operate without hindrance It is the smooth extended end of the ducting When installing Back Draft Fins...

Page 18: ...Amp 8 Flexi Ducting must be pulled taut DO NOT crush or kink the ducting 9 Connect flexi ducting to the outlet on rangehood using ring clamp Please DO NOT rip the ducting Pictures are for illustrative...

Page 19: ...istance from cooktop to the rangehood Speed of food liquid heating Filter size larger canopy preferred Quality of pots or cookware you are using high quality recommended How to reduce the possibility...

Page 20: ...t bulbs should be firmly in position Check light bulbs Make sure they are not broken or faulty Please make sure there is no obstruction in ducting or with the back draft fins Check the outlet make sur...

Page 21: ...ss to the appliance at their expense Service Lodging an Online Service Request In the event that the failure is not due to the faults mentioned in the Troubleshooting section you can lodge an online S...

Page 22: ...ion_ Page 22 9 Specifications Technical Specifications Model IS4160S Feeding Voltage 220 240V 50Hz Lamp Power LED W 2 x 3W Dimensions 270 280 898 40 660 Min 600 Max 1030 142 243 75 256 1 355 Outlet Bo...

Page 23: ...be found with the Isodrive Motor or online at schweigen com au Schweigen Home Appliances has presented this information in good faith to all their retailers and distributors to convey before any all p...

Page 24: ...rive Dingley Village Victoria 3172 Phone 1300 881 693 Email sales schweigen com au Web www schweigen com au New Zealand 5 Tolich Place Henderson Auckland 0610 Phone 0800 200 510 Email info parex emers...

Reviews: