Summary of Contents for AG-HA-6500

Page 1: ...AG HA 6500 GASOLINE GENERATOR OWNER S MANUAL BEFORE OPERATIGN THIS EQUIPMENT PLEASE READ THESE INSTRUCTIONS CAREFULLY...

Page 2: ...erator will be mounted in a closed room relevant safety regulations against fire and explosion should be followed 6 Do not connect to household circuit 7 Do not use in wet condition 8 Keep in flammabl...

Page 3: ...d connection terminal 16 DC output terminal 17 DC circuit breaker 2 Checks before Operating 1 Check the engine oil level Notice Stop the generator in a smooth place then check the generator Engine oil...

Page 4: ...should add some engine oil Add the engine oil to the upper limit of ruler Fix the engine oil plug ruler properly 2 Check the fuel level Check the fuel gauge and refill the tank if the fuel level is l...

Page 5: ...fuel valve to ON position 3 Turn the wind block color rod to CHOKE position 4 Turn the engine switch to ON position 5 Pull the starting handle slightly until you feel some resistance then put forth y...

Page 6: ...5 4 Operating Methods of Generator In order to keep your generator in good condition Please follow the rules 1 Avoid improper operation make sure to make your generator ground connection...

Page 7: ...6 2 Electrical equipments motor driven devices will produce lots of electric current when they start The following form will give you a reference when you connect them to generator...

Page 8: ...nnect from high electric current to low electric current successively When using extension lines or mobile distribution networks the total length of lines for a cross section of 1 5mm 2 should not exc...

Page 9: ...connect the generator to the family power you should ask electricians to fix it After connecting the load to the generator check if the connection is right otherwise it will cause damages of fires Al...

Page 10: ...rn the AC circuit breaker to the OFF position 2 Turn the engine switch to the OFF position 3 Turn the fuel valve to the OFF position Notice If you want to stop the engine emergently please turn the en...

Page 11: ...Every year or 300 Hrs Engine oil Inspection Change Air cleaner element Inspection Cleaning 1 Fuel filter cleaning Spark plug maintenance Valve clearance adjustment 2 Combustion chamber and valve clean...

Page 12: ...e skin cancer if repeatedly left in contact with the skin for prolonged periods Although this is unlikely unless you handle used oil on a daily basis it is still advisable to thoroughly wash your hand...

Page 13: ...flash point solvents for cleaning the air cleaner element A fire or explosion could result CAUTION Never run the generator without the air cleaner Rapid engine wear will result 1 Unsnap the air cleane...

Page 14: ...ean any dirt from around the spark plug base 3 Use the wrench supplied in the tool kit to remove the spark plug 4 Visually inspect the spark plug Discard it if the insulator is cracked or chipped Clea...

Page 15: ...ted CAUTION The spark plug must be securely tightened An improperly tightened plug can become very hot and possibly damage the generator Never use a spark plug with an improper heat range 4 Fuel filte...

Page 16: ...vapor or spilled fuel may ignite Before storing the unit for an extended period 1 Be sure the storage area is free of excessive humidity and dust 2 Drain the fuel a With the fuel valve OFF remove and...

Page 17: ...grip until resistance is felt At this point the piston is coming up on its compression stroke and both the intake and exhaust valves are closed Storing the engine in this position will help to protec...

Page 18: ...17 8 Trouble shooting When the engine will not start...

Page 19: ...18 No electricity at the receptacles No electricity at the DC terminals...

Page 20: ...19 GASOLINE GENERATOR SET Type AG HA 6500 AC voltage 110 230V 50Hz AC output 5000W Power factor 1 0 Max AC output 5500W Speed 3000 r min Weight 83 kg Max temperature 40 IP23 Max Attitude 1000 m Bj2010...