background image

GP-MCH9-BX-10A 

SCH-90 / IC-90 Manual 

R.D: SEPT 2005 

RL:10 

KH

Page 17 

Some Authorities do not allow certain warranty exclusions or limitations on how long a warranty lasts or the exclusions or limita-
tions of incidental or consequential damages.  In such cases, the above limitations or exclusions may not apply to you and are not 
intended to do so where prohibited by law.  This warranty gives you specific legal rights.  You may also have other rights which
vary by each jurisdiction. 

                                                              5285 BRADCO BLVD.    MISSISSAUGA, ON,    L4W 2A6 

                                                              2 SCHWANK WAY, WAYNESBORO,  GEORGIA.  30830-8336 

SCHWANK INC.             Ph: 905-712-4766      Fax: 905-712-8336 

INFRASAVE INC.           Ph: 1-866– INFRASV (463 7278)    Fax: 1-866-724 –9265 

LIMITED WARRANTY CERTIFICATE

FOR GAS-FIRED INFRA-RED CONSTRUCTION HEATER :  SCH  / IC SERIES

The Manufacturer warrants that this product is free from defects in material or workmanship under normal use and service subject to 
the terms of this document. 

ONE YEAR WARRANTY

Subject to the conditions and limitations stated herein, during the term of this limited warranty, we will supply any component part 
(at our option a new or repaired component part) of the heater, as defined below, excluding any labor, which the Manufacturer’s ex-
amination determines to be defective in workmanship or material for a period of one year (1 year) from the date of installation,
unless otherwise specified below. This warranty applies to the heater’s original owner, and subsequent transferees and only if the 
unit is installed and operated in accordance with the printed instructions accompanying the unit and in compliance with all applica-
ble installation, building codes and good trade practices. 

BURNER AND MANTLE - ONE YEAR WARRANTY

The manufacturer warrants the burner and ceramic tile for a period of one year. (1 year) 

WHAT IS NOT COVERED

The Manufacturer shall not be responsible for any expenses, including service, labor, diagnosis, analysis, material or transportation 
charges incurred during removal or reinstallation of this product, or any of its components or parts.  All labor or service charges shall 
be paid by the owner.  This warranty does not cover heating products improperly installed, misused, exposed to or damaged by neg-
ligence, accident, corrosive or contaminating atmosphere, water (except STW-JZ / IW), excessive thermal shock, impact, abrasion,
normal wear due to use, alteration or operation contrary to the owner’s manual or if the serial number has been altered, defaced or 
removed.  This warranty shall not apply if the input to the heating product exceeds by more than 2% of the rated input on the rating 
plate.  The Manufacturer shall not be liable for any default or delay in performance by its warranty caused by any contingency be-
yond its control, including war, government restrictions, or restraints, strikes, fire, flood, acts of God, or short or reduced supply of 
raw materials or products.

WARRANTY PROCEDURE

To establish the installation date for any purpose under this Limited Warranty, you must retain the original records that can establish 
the installation date of your unit. If you do not provide such documents, the start date of the term of this Limited Warranty will be 
based upon  the date of unit manufacture, plus thirty (30) days. Failure to maintain the equipment through regular annual service 
maintenance by a qualified service technician shall void the warranty. 

LIMITATIONS AND EXCLUSIONS

This document contains all warranties made by the Manufacturer and may not be varied, altered or extended by any person.  There
are no promises, or agreements extending from the Manufacture other than the statements contained herein.  THIS WARRANTY IS 
IN LIEU OF ALL WARRANTIES EXPRESSED OR IMPLIED, TO THE EXTENT AUTHORIZED BY THE LAWS OF THE  
JURISDICTION, INCLUDING SPECIFICALLY THE WARRANTIES OR MERCHANTIBILITY OF FITNESS FOR A PAR-
TICULAR PURPOSE. 
It is understood and agreed that the Manufacturer’s obligation hereunder is limited to repairing or replacing parts determined to be 
defective as stated above. In no event shall the Manufacturer be responsible for any alleged personal injuries or other special, inci-
dental or consequential damages. As to property damages, contract, tort or other claim the Manufacturer’s responsibility shall not 
exceed the purchase priced paid for the product. 
All replacement parts will be warranted  for the unused portion of the warranty coverage period remaining on the applicable unit. 

GP-DCHX-BX-03A 

SCH / IC WARRANTY  

AUGUST 2005 

RL: 3 

KH

Summary of Contents for IC-90 Series

Page 1: ...90 IC 90 Manual R D SEPT 2005 RL 10 KH Page 1 GAS FIRED INFRA RED HEATERS CONSTRUCTION INSTALLATION OWNER S MANUAL IC 90 SERIES SCH 90 CAUTION Read all instructions before use Retain this manual for...

Page 2: ...rs com http www schwankheaters com InfraSave Inc Mississauga Ontario Waynesboro Georgia Phone 1 866 INFRASV 463 7278 Fax 1 866 724 9265 http www infrasave com e mail info infrasave com NOTICE The Manu...

Page 3: ...mbustibles 48 side Pressure W C 11 3 LP No electric power required Also available in 200 000 BTU TABLE OF CONTENTS INFORMATION AND SAFETY LABELS 4 1 0 INSTALLATION REQUIREMENTS 6 1 1 GENERAL INSTRUCTI...

Page 4: ...GP MCH9 BX 10A SCH 90 IC 90 Manual R D SEPT 2005 RL 10 KH Page 4...

Page 5: ...nce WHAT TO DO IF YOU SMELL GAS x DO NOT try to light any appliance x DO NOT touch any electrical equipment x DO NOT use any telephone equipment in the immediate area x Immediately call your gas suppl...

Page 6: ...er and to replace any part which has been under water x Any changes to this heater or the heater s controls can be very dangerous x Any part removed must be replaced prior to operating the heater x Fa...

Page 7: ...quires 90 sq in of opening for combustion air ex 9 x 10 window opening To maintain the carbon dioxide content in the air at or below the concentration mentioned above the number of air changes are lis...

Page 8: ...l codes JOIST NO LESS THAN 2 X 6 3 16 DRILL BIT 3 8 DIAMETER EYEHOOK DRIVE THREADED PORTION FULLY INTO JOIST THICKNESS 2 MINIMUM CAUTION WARNING FIGURE 2 FREE STANDING FLOOR MOUNT A steel rod non comb...

Page 9: ...ker Only MAINTENANCE See page 9 1 Pre purge gas line prior to lighting 2 Place knob in the OFF position rotate knob 1 notch or click counter clockwise Depress and hold the control knob Light pilot thr...

Page 10: ...out within three minutes 2 0 MAINTENANCE This heater should be cleaned at least once annually with a dry cloth This heater should be inspected before each use and at least once annually by a qualified...

Page 11: ...upply Re light pilot and continue using the construction heater as before Replace filter at least once every 2 weeks minimum once a day when sanding drywall each time when connecting heater at differe...

Page 12: ...0407 LP 12 PILOT TUBE JH 0463 XX JH 0463 XX 13 THERMOCOUPLE JH 0403 XX JH 0403 XX 14 BLACK WIRE ASSEMBLY NOT SHOWN JH 0465 XX JH 0465 XX 15 SAFETY TIP SWITCH JH 0405 XX JH 0405 XX 16 1 2 VALVE INLET E...

Page 13: ...GP MCH9 BX 10A SCH 90 IC 90 Manual R D SEPT 2005 RL 10 KH Page 13 FIGURE 4 REPLACEMENT PARTS DIAGRAM FOR SCH 90 N L IC 90 N L 1 3 2 24 25 23 16 4 12 13 18 22 15 8 6 5 7 9 17...

Page 14: ...H 0418 NG JH 0418 XX 10 PILOT BURNER NOT SHOWN JH 0406 XX JH 0406 XX 11 PILOT ORIFICE HONEYWELL NOT SHOWN JH 0407 NG JH 0407 LP 12 PILOT TUBE JH 0463 XX JH 0463 XX 13 MILLIVOLT GENERATOR POWERPILE JH...

Page 15: ...GP MCH9 BX 10A SCH 90 IC 90 Manual R D SEPT 2005 RL 10 KH Page 15 FIGURE 5 REPLACEMENT PARTS DIAGRAM FOR SCH 90 M N L IC 90 M N L 2 7 9 4 16 12 13 17 15 6 8 22 21 18 3 1 5...

Page 16: ...GP MCH9 BX 10A SCH 90 IC 90 Manual R D SEPT 2005 RL 10 KH Page 16...

Page 17: ...ucts improperly installed misused exposed to or damaged by neg ligence accident corrosive or contaminating atmosphere water except STW JZ IW excessive thermal shock impact abrasion normal wear due to...