6. A SAFE LOCATION FOR THE HEATER
Caution:
When objects are left under a heater in operation, such objects will be subject to radiant heat
and could be damaged.
The main application of this heater is to provide radiant heat comfort in the outdoors, at poolside,
spa areas, terraces, patios and work areas, etc. It is necessary to provide “wind breakers”, against
wind and breezes.
NOTE : This heater is approved for outdoor use only
•
Respect minimum clearances to combustibles as shown in figure 12 below.
•
Install heater on a levelled, solid and stable surface.
•
Do not install in an explosive environment. Keep away from areas where gas vapours
are present or inflammable liquids are stored or used.
•
In case of high winds, completely shut-off the heater and the cylinder gas valve. Remove reflec-
tor dome.
•
Do not move the heater when it is hot.
The clearances to combustibles are established at
points reaching a surface temperature of 160° F.
Some materials such as awnings or plastic may
require higher distances.
Respect clearances as shown:
•
Sides of Reflector: 24 inches
•
Above Reflector: 18 inches
•
Below Reflector: 24 inches
Fig. 12
6.1 CLEARANCES FROM COMBUSTIBLES
18”
24”
24”
24”