![Schwaiger ZHS19 Manual Download Page 3](http://html.mh-extra.com/html/schwaiger/zhs19/zhs19_manual_1216226003.webp)
Congratulations and thank you for purchasing the Schwaiger
ZHS19 product. Below you will find useful operating guidelines.
4. Installation of Door/Window Sensor
Select a place for installation. Remove the pro-
tective cover and stick the bracket to the place
desired. The sensor should be installed at an im-
movable place, e.g. a door frame. The magnet
can be installed on either side of the sensor at
the movable part of the location (e.g. door panel,
see example).
The distance between sensor and magnet should
not exceed 15 mm.
5. Attach the sensor to the bracket
6. Network removal of the device
Put the Gateway into removal mode by choosing
„Home setup“ in the main menu and then click on
„Add device“ (See images on the left). Then reset
the device to default settings.
7. Reset to default settings
Press the networking button for 5 seconds until
the green LED starts to flash slowly.
Note: For network inclusion, the sensor must
always be in the factory state.
LED indicator of devices
3. Networking button
Press the networking button (within the hole)
for 2 seconds until the green LED starts to
flash fast, then let go. The device will be de-
tected and included into the network.
This is a smart door and window sensor which is based on the ZigBee Wireless Network-
ing technology. It has a very low power consumption which makes for longer battery life.
The sensor detects whether a door or window is opened or closed. Thanks to the dual
sensor design, installation is even more flexible and adaptable.
Network inclusion
1. Remove the protective
battery cover
2. Put the Gateway into inclusion mode
Network inclusion
Press the networking button for 2
seconds until the green LED starts to flash
(two times per second)
Network removal / Reset
The green LED flashes 6 times
(once per second)
Alarm (anti-tamper key)
The red LED flashes once
Network inclusion of the sensor
Put the Gateway into inclusion mode.
Remove the protective battery cover, press the networking button for 2 seconds
until the green LED starts to flash fast.
Please pay attention to the fact that during network inclusion, the distance
between sensor and Gateway may not exceed 0.5 m.
Technical data
LED
indicator
Sensor
Magnet
Anti-tamper key
Working voltage
DC 3 V (2 x AAA battery)
Static current
≤ 5 µA
Alarm current
≤ 35 mA
Detecting distance
< 15 mm
Range
about 15 m (depending on building
structure)
Working environment
-10°C ~ +50°C
Transmission power
<1 mW
Frequency range
2405-2480 MHz
Sensor dimension
76 x 36.6 x 16.5 mm
Magnet dimension
76 x 13.9 x 16.5 mm
ZHS19
USER MANUAL ZHS19
DOOR AND WINDOW SENSOR
ZHS19
MANUFACTURER INFORMATION
Dear Customer,
should you require technical advice
and your retailer could not help
please contact our technical support.
Schwaiger GmbH
Würzburger Straße 17
90579 Langenzenn
Hotline: +49 (0) 9101 702-199
www.schwaiger.de