background image

3.1  Set up gun as follows 

 

 

Connect  Duo-hose  (twin  hose  for  atomising  air  and  fluid)  to  material  pressure  tank  or  other 
means of feeding fluid and to compressor. 

 

Translucent part of hose 

: for fluid (gun connection “M”) 

 

Blue part of hose 

: for atomising air (gun connection “AIR”) 

 

 

Set  atomising  air  pressure  to  required  spray  droplet  sizes  by  reducing  valve  (not  part  of  the 
spray gun). 

 

 

Set material pressure to required material outlet and spray droplet sizes by a 2. reducing valve 
(not part of the spray gun). 

 

 

 

IMPORTANT! 

 

 

Fluid output can be regulated individually, apply needle regulator (24.1) and counter nut  

  

 

(23.1) for quantity of fluid flow. 

 

 

Turning needle regulator right 

: less fluid flow 

 

 

Turning needle regulator left   

: more fluid flow 

 

When  you  are  sure  of  fluid  flow  open  trigger  (19.1).  Spray  operation  starts.  You  will  notice  that  you 
receive so called “pre-air” prior to opening fluid flow when pulling the trigger. When releasing trigger you 
still  have  “purging-air”  after  needle  has  closed  nozzle  and  fluid  flow  was  stopped.  This  prevents  that 
fluid forms drop instead of the desired atomisation. 

 

 

 

IMPORTANT! 

 

 

After spray operation give a short period of time “pre-air” respectively “purging-air”. This  

  

 

prevents that material blocked the nozzle. 

 

3.2  Operating Information 

 

 

Depending on viscosity of fluid nozzle bores are available in 0,2 ; 0,3 ; 0,5 ; 0,8 and 1,0mm 

 

(only one size of air cap is required). 

 

Standard  version  of  gun  has  flat  spray  pattern  air  cap  with  approx.  60°  sprayangle  (3.1.1).  If 
round spray is required, just replace air cap by a round spray air cap (3.1.2). 

 

Flat spray air cap can be positioned for horizontal, vertical or any in between position of jet. For 
special air caps with other sprayangels please contact the manufacturer. 

 

 

 

CAUTION! 

 

 

Never point the spray gun against persons. Wearing eye protecting is strongly  

  

 

recommended. Spraying procedures cause noises depending on the used pressure. If  

  

 

necessary, wearing of ear protection is recommended. 

 

 

 

WARNING! 

 

 

Danger caused by combustible and noxious spraying material. Safety instructions on fluid  

  

 

can and material data of fluid manufacturer must definitely be observed. 

 

Don´t  smoke  when  spraying  paints  or  solvents  which  have  combustible  properties.  All  electrical 
installations  within  the  spraying  area  must  be  explosion  proof.  Observe  working  safety  regulations  in 
respect of protective clothing (masks, clothing, ear protection, etc.). 

 

Summary of Contents for FINE-SPRAY W 3/FZ-Duo

Page 1: ...Operating Manual for FINE SPRAY gun W 3 FZ Duo Read this manual carefully before installing operating or servicing this spray gun Keep always handy for further use ...

Page 2: ...ated hydrocarbons These chemicals may react with aluminium anodised or zinced parts The chemical reaction may be explosive 2 3 Warning against Danger This operating manual warns users of operations which may put their health at risk The warnings are indicated by combinations of text and symbols corresponding to the different danger classes WARNING Signs a possible danger situation If you don t avo...

Page 3: ...MPORTANT After spray operation give a short period of time pre air respectively purging air This prevents that material blocked the nozzle 3 2 Operating Information Depending on viscosity of fluid nozzle bores are available in 0 2 0 3 0 5 0 8 and 1 0mm only one size of air cap is required Standard version of gun has flat spray pattern air cap with approx 60 sprayangle 3 1 1 If round spray is requi...

Page 4: ...always be greased slightly 4 2 Changing nozzle set A nozzle set includes needle 1 1 1 nozzle 2 1 1 and air cap 3 1 1 or 3 1 2 If nozzle size is to be changed always change all three parts Change the complete set also when only one of the parts is defect 1 Remove screw 21 1 2 Pull out valve spring 20 1 3 Pull out needle valve cartridge 4 Unscrew the collar ring 4 1 1 remove air cap 3 1 1 or 3 1 2 5...

Page 5: ...needle is sliding smoothly again within the tightening gasket If drops form on the nozzle either needle or nozzle is worn and should be replaced Or needle is not closed properly f i because of particle residues within nozzle Cleaning the needle valve cartridge with solvent see chapter 4 3 If there is an uneven and not steady spray jet make sure that nozzle is screwed in tight Other reason could al...

Page 6: ......

Page 7: ...1 410008 1 counter nut 24 1 610029 1 needle regulator 26 0 220021 2 hose socket complete 26 2 640080 2 washer 26 3 220055 2 hose socket 26 4 410030 2 nut 27 1 500019 1 buckling guard complete optional 28 1 910004 1 hook optional Part no see page 8 Please specify diameter 0 2 0 3 0 5 0 8 1 0 mm Ø 7 Technical data weight approx 240 g air consumption approx 90ltr min at 3 bar and 0 5mm nozzle max mat...

Page 8: ...zle 1 2mm 1 1 1 110078 needle 1 5mm 2 1 1 210068 nozzle 1 5mm 2 1 2 210069 nozzle 0 2mm air cap flat spray 45 draw no part no Description 3 1 1 310038 for nozzle 0 2 1 0mm 3 1 1 310039 for nozzle 1 2 1 5mm air cap flat spray 60 standard draw no part no Description 3 1 1 310032 for nozzle 0 2 1 0mm 3 1 1 310033 for nozzle 1 2 1 5mm air cap flat spray 90 draw no part no Description 3 1 1 310036 for ...

Reviews: