Maintenance and care
7.4.3 Adjustment of the pneumatic jaw end position monitoring (PM)
Jaw 1: monitoring open jaw position
• Move base jaws to OPEN position.
• Screw the set-screw (61) into the bore hole "o" up to the stop
and then unscrew it again by a few turns.
• Slowly screw the set-screw (61) into the bore hole "oo" until the
differential pressure sensor emits a switching signal.
• Hand-tighten the set-screw (61) in the bore hole "o".
• Screw set-screw (63) in both bore holes and hand-tighten.
Jaw 2: monitoring closed jaw position
• Move base jaws to CLOSED position.
• Screw the set-screw (61) into the bore hole "oo" up to the stop
and then unscrew it again by a few turns.
• Slowly screw the set-screw (61) into the bore hole "o" until the
differential pressure sensor emits a switching signal.
• Hand-tighten the set-screw (61) in the bore hole "oo".
• Screw set-screw (63) in both bore holes and hand-tighten.
35