Assembly
04.00 | SWG | Assembly and Operating Manual | en | 389453
23
X
Measure of clearance X
Size
X
SWG 10
1.2 mm
SWG 12
1.0 mm
CAUTION
Contamination at the end face will cause incorrect signals.
•
Do not use glue at the ende face of the fibre optical cable.
CAUTION
Reducing the bending radius by moving back and forth causes
changes in the signal, incorrect switchingor rupture of the cable.
•
The minimum bending radius of the fibre optical cableis
Rmin. = 50 mm.
To mount the fibre optical cable, use a suitable glue for joining
metal and plastic (e.g. Weicon Contact Gel).
Ø
Apply glue carefully to plastic bracket.
Ø
Clip in the fibre optical cable and align to
dimension X
(see