background image

Original operating manual

Assembly and operating manual
SST

Sensor tester

Summary of Contents for SST

Page 1: ...Original operating manual Assembly and operating manual SST Sensor tester ...

Page 2: ...ations for the purpose of technical improvement Document number 389581 Version 04 00 05 06 2019 en SCHUNK GmbH Co KG All rights reserved Dear Customer thank you for trusting our products and our family owned company the leading technology supplier of robots and production machines Our team is always available to answer any questions on this product and other solutions Ask us questions and challeng...

Page 3: ...al and operating conditions 5 2 3 Constructional changes 5 3 Technical data 6 4 Design and description 7 4 1 Design 7 4 2 Description 7 5 Assembly 8 6 Operation 9 6 1 Installation of a sensor on the sensor tester 9 6 1 1 Connection of a sensor with connection plug 9 6 1 2 Connection of a sensor with an open wire strand 9 6 2 Operation of the SST with a sensor 9 7 Maintenance and care 10 7 1 Mainte...

Page 4: ...in this manual 1 1 1 Applicable documents General terms of business Catalog data sheet of the purchased product The documents marked with an asterisk can be downloaded on our homepage schunk com 1 2 Warranty If the product is used as intended the warranty is valid for 24 months from the ex works delivery date under the following conditions Observe the ambient conditions and operating conditions Li...

Page 5: ...chnical data and installation and operation notes in this manual and to comply with the maintenance intervals 2 2 Environmental and operating conditions Make sure that the environment is free from splash water and vapors as well as from abrasion or processing dust Exceptions are products that are designed especially for contaminated environments 2 3 Constructional changes Implementation of structu...

Page 6: ...529 EN 60529 Connection type M8 and M12 cable socket with 0 4 m cable Measurement operating voltage VDC 9 compound battery 6LR61 Internal operating voltage VDC 15 Connection options Inductive capacitive and optoelec tronic sensors 3 conductor DC 2 conductor DC and NAMUR More technical data is included in the catalog data sheet Whichever is the latest version ...

Page 7: ...pen wire strands 5 Connection for sensor with M12 connecting plug 6 Connection for sensor with M8 connecting plug 4 2 Description The SST sensor tester enables the rapid testing and adjustment of inductive sensors magnetic switches and reed contacts The switching function is signaled by an LED and an additional acoustic signal When not in use the sensor tester automatically switches itself off aft...

Page 8: ...Assembly 8 04 00 SST Assembly and operating manual en 389581 5 Assembly The Sensor tester SST can be fastened by means of the lateral through bores if necessary 1 Through bores Ø 5 5 ...

Page 9: ...he GND sensor Ø Check whether the wire colors of the sensor correspond to the descriptions in the table Ø Connect wires to the spring type terminals 6 2 Operation of the SST with a sensor The sensor to be tested is connected Ø Adjust PNP NPN switch 1 according to the sensor type Ø Actuate the ON button 2 LED 3 lights up green If the LED 3 lights up in red the battery needs to be changed Ø If the s...

Page 10: ...equire maintenance 7 2 Battery change Ø Using a screwdriver press against the lock on the cover of the battery compartment and open the battery compartment cover Ø Remove old batteries and dispose of them properly Ø Insert new battery Battery type 9V compound battery 6LR61 Ø Close the battery compartment cover and snap the lock in place ...

Page 11: ...581 11 8 Troubleshooting Error Possible cause Corrective action No LED lights up The battery is empty or does not have contact The red LED lights up The battery is almost empty Change the battery Orange LED lights up continuously PNP NPN switch is set incorrectly ...

Page 12: ...12 04 00 SST Assembly and operating manual en 389581 ...

Reviews: