![SCHUNK SRU-plus20-60 Assembly And Operating Manual Download Page 46](http://html.mh-extra.com/html/schunk/sru-plus20-60/sru-plus20-60_assembly-and-operating-manual_1216060046.webp)
Assembly
46
11.00 | SRU-plus 20 - 60 | Assembly and Operating Manual | en | 389443
5.5.2 Mounting MMS 22 magnetic switch
CAUTION
Material damage due to an incorrect tightening torque!
If the threaded pin is tightened with an incorrect tightening
torque, the product may be damaged.
•
Observe a maximum tightening torque of 10 Ncm for the set-screws.
The sensors can be mounted via four grooves in the housing of the
product.
We recommend the use of four magnetic switches to monitor the
center position:
• Monitoring the end position
A
• Monitoring the end position
B
• Monitoring for the approach to the center position from end position
A
• Monitoring for the approach to the center position from end position
B