Troubleshooting
38
10.00 | SRU | Assembly and Operating Manual | en | 389439
7.3 Product rotates jerkily
Possible cause
Corrective action
Too little grease in the mechanical guiding
areas.
Compressed air lines blocked.
Check compressed air lines of damage.
Mounting surface is not sufficiently flat.
Check the evenness of the mounting surface.
One-way flow control valve is missing or
adjustet incorrectly.
Install and adjust one-way flow control
valve.
Loading too large.
Check the permissible weight.,
7.4 Torque diminishes?
Possible cause
Corrective action
Compressed air can escape.
Check seals, if necessary, disassemble the
product and replace seals.
Too much grease in the mechanical
movement space.
Clean and lubricate product.
Pressure drops below minimum.
Check air supply.